FXMQ200AFVM is a Daikin indoor unit in the FXMQ-AFVM series, outdoor air processing unit type. Its rated cooling capacity is 22.4 kW according to catalogue PCVVN2507Aaprv.
- Rated cooling capacity
- 22.4 kW
- Power supply
- 1 phase, 220-240/220-230 V, 50/60 Hz
- Dimensions (H×W×D)
- 300×1,400×700 mm
- Weight
- 47 kg
Data extracted from the English catalogue; not all specifications have been manually verified. Check the source before use. Source & notes →
FXMQ200AFVM specifications
| Rated capacity 4 specifications | |
|---|---|
| Cooling capacity *1 · Btu/h | 76,400 |
| Cooling capacity *1 · kW | 22.4 |
| Heating capacity *1 · Btu/h | 68,200 |
| Heating capacity *1 · kW | 20.0 |
| Electrical & efficiency 3 specifications | |
| Power supply | 1 phase, 220-240/220-230 V, 50/60 Hz |
| Power consumption · Cooling · kW | 0.115 |
| Power consumption · Heating · kW | 0.155 |
| Airflow & sound 5 specifications | |
| Fan · Motor output · kW | 0.350 |
| Fan · Airflow rate (H/M/L) · m³/min | 29.0/21.8/14.5 |
| Fan · Airflow rate (H/M/L) · cfm | 1,024/770/512 |
| Fan · External static pressure · Pa | Rated 100 (200-50) |
| Sound level (H/M/L) *3 · dB(A) | 42/35/26 |
| Dimensions & weight 3 specifications | |
| Casing | Galvanised steel plate |
| Dimensions (H×W×D) · mm | 300×1,400×700 |
| Machine weight · kg | 47 |
| Piping & refrigerant 3 specifications | |
| Refrigerant piping · Liquid · mm | 9.5 (Flare) |
| Refrigerant piping · Gas · mm | 19.1 (Brazing) |
| Refrigerant piping · Drain · mm | VP25 (External dia. 32, Internal dia. 25) |
| Operating conditions 2 specifications | |
| Operation range *4 · Cooling · °CDB | 15 to 43 |
| Operation range *4 · Heating · °CDB | -5 to 19 |
| Filters 6 specifications | |
| Air filter | *2 |
| Filters · MERV8 filter | BAF376B160 |
| Filters · MERV14 filter | BAF377B160 |
| Filters · Filter chamber for MERV8/14 filter | KDDF37AB160 |
| Filters · Long-life replacement filter | KAF371B160 |
| Filters · Streamer duct chamber | BDEZ500A510VE |
| Controls & accessories 17 specifications | |
| lortnoc/noitarepO · Wired remote controller | BRC1H63W(K) / BRC1E63 / BRC2E61 |
| lortnoc/noitarepO · Wireless remote controller *4 | Cooling only: BRC4C66 / Heat pump: BRC4C65 |
| lortnoc/noitarepO · Remote sensor (for indoor temperature) | BRCS01A-6 |
| lortnoc/noitarepO · Simple touch controller | DTP401A61 |
| lortnoc/noitarepO · AC adaptor for simple touch controller | DTP401A62 |
| lortnoc/noitarepO · Central remote controller | DCS302CA61 |
| lortnoc/noitarepO · Unified ON/OFF controller | DCS301BA61 |
| lortnoc/noitarepO · Schedule timer | DST301BA61 |
| Service panel | KTBJ25K160F |
| Air discharge adaptor | KDAJ25K140A |
| Adaptor for wiring (operation status output) | BRP11B62 |
| Wiring adaptor for electrical appendices (1) | KRP2A61 |
| Wiring adaptor for electrical appendices (2) | KRP4AA51 |
| Installation box for adaptor PCB *1 | KRP4A96 *2, 3 |
| External control adaptor for outdoor unit | DTA104A61 |
| Adaptor for multi tenant (24V type) | DTA114A61 |
| Digital input adaptor for hotel application | BRP7A53 |
No matching specifications. Try another search term.
Catalogue source & rating conditions
Values are taken from PCVVN2507Aaprv, PDF page 237 (printed page 236). General Catalogue 2025; published on VRV.vn as Catalogue 2026 (EN).
Rated performance depends on test conditions and system combinations. Check the source notes when selecting equipment or comparing series.
Read original source notes (English)
Notes:
*1. The capacity is the maximum value under the following conditions:
• Cooling: Indoor temp. of 33°CDB, 28°CWB, Outdoor temp. of 33°CDB.
• Heating: Indoor temp. 0°CDB, -2.9°CWB, Outdoor temp. 0°CDB, -2.9°CWB.
• Equivalent reference piping length: 7.5 m (0 m horizontal)
• The rated external static pressure and air volume are set in ().
*2. An intake filter is not supplied, so be sure to install the optional filter.
*3. Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
These values are normally somewhat higher during actual operation as a result of ambient conditions.
*4. The operation range can be extended to 15°C in cooling operation and 19°C in heating operation by field setting.
When fresh air intake mode is enabled during cooling operation, operation range cannot be extended. (limit at 19 to 43°C)
Options
Model FXMQ80AFVM FXMQ140AFVM FXMQ200AFVM FXMQ250AFVM
Wired remote controller BRC1H63W(K) / BRC1E63 / BRC2E61
Wireless remote controller *4 Cooling only: BRC4C66 / Heat pump: BRC4C65
Remote sensor (for indoor temperature) BRCS01A-6
Simple touch controller DTP401A61
AC adaptor for simple touch controller DTP401A62
Central remote controller DCS302CA61
Unified ON/OFF controller DCS301BA61
Schedule timer DST301BA61
236
lortnoc/noitarepO
sretliF
m³/min 11.5/8.6/5.8 20.5/15.4/10.3 29.0/21.8/14.5 36.0/27.0/18.0
MERV8 filter BAF376B56 BAF376B80 BAF376B160
MERV14 filter BAF377B56 BAF377B80 BAF377B160
Filter chamber for MERV8/14 filter KDDF37AB56 KDDF37AB80 KDDF37AB160
Long-life replacement filter KAF371B56 KAF371B80 KAF371B160
BDEZ500A140VE
Streamer duct chamber BDEZ500A140VE BDEZ500A510VE
BDEZ500A510VE
Service panel KTBJ25K56F KTBJ25K80F KTBJ25K160F
Air discharge adaptor KDAJ25K56A KDAJ25K71A KDAJ25K140A
Adaptor for wiring (operation status output) BRP11B62
Wiring adaptor for electrical appendices (1) KRP2A61
Wiring adaptor for electrical appendices (2) KRP4AA51
Installation box for adaptor PCB *1 KRP4A96 *2, 3
External control adaptor for outdoor unit DTA104A61
Adaptor for multi tenant (24V type) DTA114A61
Digital input adaptor for hotel application BRP7A53
Notes:
*1. Installation Box ☆ is necessary for each adaptor marked ★.
*2. Up to 2 adaptors can be fixed for each installation box.
*3. Only one installation box can be installed for each indoor unit.
*4. Remote sensor is necessary when using wireless remote controller.
tnempiuqE
tnemtaerT
riA
Air Treatment Equipment
View catalogue page · PDF 237
The original page preserves symbols, merged cells and accessories; not every accessory shown is supplied with the unit.

Read all text from this page and its facing page
PDF page 237
Specifications
Model FXMQ80AFVM FXMQ140AFVM FXMQ200AFVM FXMQ250AFVM
Power supply 1 phase, 220-240/220-230 V, 50/60 Hz
Btu/h 30,700 54,600 76,400 95,500
Cooling capacity *1
kW 9.0 16.0 22.4 28.0
Btu/h 27,600 47,800 68,200 85,300
Heating capacity *1
kW 8.1 14.0 20.0 25.0
Cooling 0.080 0.100 0.115 0.180
Power consumption kW
Heating 0.095 0.125 0.155 0.225
Casing Galvanised steel plate
Dimensions (H×W×D) mm 300×700×700 300×1,000×700 300×1,400×700
Motor output kW 0.140 0.350
Fan Airflow rate (H/M/L)
cfm 406/304/205 724/544/364 1,024/770/512 1,271/953/635
External static pressure Pa Rated 100 (200-50)
Air filter *2
Liquid 9.5 (Flare)
Refrigerant piping Gas mm 15.9 (Flare) 19.1 (Brazing) 22.2 (Brazing)
Drain VP25 (External dia. 32, Internal dia. 25)
Machine weight kg 29 37 47 48
Sound level (H/M/L) *3 dB(A) 37.5/30/23 41/34/25 42/35/26 44/36/27
Cooling 15 to 43
Operation range *4 °CDB
Heating -5 to 19
Notes:
*1. The capacity is the maximum value under the following conditions:
• Cooling: Indoor temp. of 33°CDB, 28°CWB, Outdoor temp. of 33°CDB.
• Heating: Indoor temp. 0°CDB, -2.9°CWB, Outdoor temp. 0°CDB, -2.9°CWB.
• Equivalent reference piping length: 7.5 m (0 m horizontal)
• The rated external static pressure and air volume are set in ().
*2. An intake filter is not supplied, so be sure to install the optional filter.
*3. Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
These values are normally somewhat higher during actual operation as a result of ambient conditions.
*4. The operation range can be extended to 15°C in cooling operation and 19°C in heating operation by field setting.
When fresh air intake mode is enabled during cooling operation, operation range cannot be extended. (limit at 19 to 43°C)
Options
Model FXMQ80AFVM FXMQ140AFVM FXMQ200AFVM FXMQ250AFVM
Wired remote controller BRC1H63W(K) / BRC1E63 / BRC2E61
Wireless remote controller *4 Cooling only: BRC4C66 / Heat pump: BRC4C65
Remote sensor (for indoor temperature) BRCS01A-6
Simple touch controller DTP401A61
AC adaptor for simple touch controller DTP401A62
Central remote controller DCS302CA61
Unified ON/OFF controller DCS301BA61
Schedule timer DST301BA61
236
lortnoc/noitarepO
sretliF
m³/min 11.5/8.6/5.8 20.5/15.4/10.3 29.0/21.8/14.5 36.0/27.0/18.0
MERV8 filter BAF376B56 BAF376B80 BAF376B160
MERV14 filter BAF377B56 BAF377B80 BAF377B160
Filter chamber for MERV8/14 filter KDDF37AB56 KDDF37AB80 KDDF37AB160
Long-life replacement filter KAF371B56 KAF371B80 KAF371B160
BDEZ500A140VE
Streamer duct chamber BDEZ500A140VE BDEZ500A510VE
BDEZ500A510VE
Service panel KTBJ25K56F KTBJ25K80F KTBJ25K160F
Air discharge adaptor KDAJ25K56A KDAJ25K71A KDAJ25K140A
Adaptor for wiring (operation status output) BRP11B62
Wiring adaptor for electrical appendices (1) KRP2A61
Wiring adaptor for electrical appendices (2) KRP4AA51
Installation box for adaptor PCB *1 KRP4A96 *2, 3
External control adaptor for outdoor unit DTA104A61
Adaptor for multi tenant (24V type) DTA114A61
Digital input adaptor for hotel application BRP7A53
Notes:
*1. Installation Box ☆ is necessary for each adaptor marked ★.
*2. Up to 2 adaptors can be fixed for each installation box.
*3. Only one installation box can be installed for each indoor unit.
*4. Remote sensor is necessary when using wireless remote controller.
tnempiuqE
tnemtaerT
riA
Air Treatment Equipment
FACING PAGE — PDF page 236
Air Treatment Equipment
Outdoor-Air Processing Unit (Room Temperature Control Type)
Extended operation range
The outdoor operation temperature range extended from 19 to 15°CDB during cooling operation and
from 15 to 19°CDB during heating operation*.
This enables reliable operation even under wider temperature conditions.
Outdoor air temperature (°CDB)
32
100 % H R u e
%
m la t i
R
d iv
e
i e t
l
y ative Hu midity
90
Outdoor
Air
(°
T
C
e W m B p )
erature
S O up p p e o ra r t t i e o d n C R o a o n l g in e g
E
C
H
x
o
e
t
o
a
e
l
t
n
i
i
n
n
d
g
g
e
:
:
d
1
- 5
o
5
°
p
°
C
C
e
D
D
ra
B
B
t i
t
t
o
o
o
n
1
4
r
9
3
a
°
°
n
C
C
g
D
D
e
B
B
:
Su O p p p e o ra rt t e io d n H R e a a n ti g n e g
Op F e a ra n tion
30%
Relative Humidity 20% H u R m el i a d t i i t v y e
–5 15 19 (33.5) 43
* Thermo-off (fan) operation starts automatically when cooling 19°CDB or less / heating15°CDB or more.
In case of cooling mode, operation range can be extended to 15°CDB by field setting.
In case of heating mode, operation range can be extended to 19°CDB by field setting
High efficiency filter (MERV8/MERV14) (Option)
The filter options of MERV8 and MERV14 are available.
The high efficiency filter can help remove infectious aerosol in the air.
MERV8 filter MERV14 filter