TECHNICAL SPECIFICATION SHEET · DAIKIN
FXMQ200AFVM
Indoor unit · FXMQ-AFVM · Outdoor air processing unit
Data extracted from the English catalogue; not all specifications have been manually verified. Check the original source before use.
| Rated capacity | |
|---|---|
| Cooling capacity *1 · Btu/h | 76,400 |
| Cooling capacity *1 · kW | 22.4 |
| Heating capacity *1 · Btu/h | 68,200 |
| Heating capacity *1 · kW | 20.0 |
| Electrical & efficiency | |
| Power supply | 1-phasese, 220-240/220-230 V, 50/60 Hz |
| Power consumption · Cooling · kW | 0.115 |
| Power consumption · Heating · kW | 0.155 |
| Airflow & sound | |
| Fan · Motor output · kW | 0.350 |
| Fan · Airflow rate (H/M/L) · m³/min | 29.0/21.8/14.5 |
| Fan · Airflow rate (H/M/L) · cfm | 1,024/770/512 |
| Fan · External static pressure · Pa | Rated 100 (200-50) |
| Sound level (H/M/L) *3 · dB(A) | 42/35/26 |
| Dimensions & weight | |
| Casing | Galvanised steel plate |
| Dimensions (H×W×D) · mm | 300×1,400×700 |
| Machine weight · kg | 47 |
| Piping & refrigerant | |
| Refrigerant piping · Liquid · mm | 9.5 (Flare) |
| Refrigerant piping · Gas · mm | 19.1 (Brazing) |
| Refrigerant piping · Drain · mm | VP25 (External dia. 32, Internal dia. 25) |
| Operating conditions | |
| Operation range *4 · Cooling · °CDB | 15 to 43 |
| Operation range *4 · Heating · °CDB | -5 to 19 |
| Filters | |
| Air filter | *2 |
| Filters · MERV8 filter | BAF376B160 |
| Filters · MERV14 filter | BAF377B160 |
| Filters · Filter chamber for MERV8/14 filter | KDDF37AB160 |
| Filters · Long-life replacement filter | KAF371B160 |
| Filters · Streamer duct chamber | BDEZ500A510VE |
| Controls & accessories | |
| lortnoc/noitarepO · Wired remote controller | BRC1H63W(K) / BRC1E63 / BRC2E61 |
| lortnoc/noitarepO · Wireless remote controller *4 | Cooling only: BRC4C66 / Heat pump: BRC4C65 |
| lortnoc/noitarepO · Remote sensor (for indoor temperature) | BRCS01A-6 |
| lortnoc/noitarepO · Simple touch controller | DTP401A61 |
| lortnoc/noitarepO · AC adaptor for simple touch controller | DTP401A62 |
| lortnoc/noitarepO · Central remote controller | DCS302CA61 |
| lortnoc/noitarepO · Unified ON/OFF controller | DCS301BA61 |
| lortnoc/noitarepO · Schedule timer | DST301BA61 |
| Service panel | KTBJ25K160F |
| Air discharge adaptor | KDAJ25K140A |
| Adaptor for wiring (operation status output) | BRP11B62 |
| Wiring adaptor for electrical appendices (1) | KRP2A61 |
| Wiring adaptor for electrical appendices (2) | KRP4AA51 |
| Installation box for adaptor PCB *1 | KRP4A96 *2, 3 |
| External control adaptor for outdoor unit | DTA104A61 |
| Adaptor for multi tenant (24V type) | DTA114A61 |
| Digital input adaptor for hotel application | BRP7A53 |
Source reference
PCVVN2507Aaprv · PDF page 237 · Printed page 236
General Catalogue 2025; published on VRV.vn as Catalogue 2026 (EN)
Open catalogue PDF · page 237
Model page: https://vrv.vn/spec/fxmq200afvm/
Rated performance depends on test conditions and system combinations. “—” means no value was extracted. This sheet does not replace the manufacturer’s technical documentation.
Original source notes
Extracted from the catalogue page and its facing page, where available. Notes may refer to other models or optional accessories.
Notes: *1. The capacity is the maximum value under the following conditions: • Cooling: Indoor temp. of 33°CDB, 28°CWB, Outdoor temp. of 33°CDB. • Heating: Indoor temp. 0°CDB, -2.9°CWB, Outdoor temp. 0°CDB, -2.9°CWB. • Equivalent reference piping length: 7.5 m (0 m horizontal) • The rated external static pressure and air volume are set in (). *2. An intake filter is not supplied, so be sure to install the optional filter. *3. Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. These values are normally somewhat higher during actual operation as a result of ambient conditions. *4. The operation range can be extended to 15°C in cooling operation and 19°C in heating operation by field setting. When fresh air intake mode is enabled during cooling operation, operation range cannot be extended. (limit at 19 to 43°C) Options Model FXMQ80AFVM FXMQ140AFVM FXMQ200AFVM FXMQ250AFVM Wired remote controller BRC1H63W(K) / BRC1E63 / BRC2E61 Wireless remote controller *4 Cooling only: BRC4C66 / Heat pump: BRC4C65 Remote sensor (for indoor temperature) BRCS01A-6 Simple touch controller DTP401A61 AC adaptor for simple touch controller DTP401A62 Central remote controller DCS302CA61 Unified ON/OFF controller DCS301BA61 Schedule timer DST301BA61 236 lortnoc/noitarepO sretliF m³/min 11.5/8.6/5.8 20.5/15.4/10.3 29.0/21.8/14.5 36.0/27.0/18.0 MERV8 filter BAF376B56 BAF376B80 BAF376B160 MERV14 filter BAF377B56 BAF377B80 BAF377B160 Filter chamber for MERV8/14 filter KDDF37AB56 KDDF37AB80 KDDF37AB160 Long-life replacement filter KAF371B56 KAF371B80 KAF371B160 BDEZ500A140VE Streamer duct chamber BDEZ500A140VE BDEZ500A510VE BDEZ500A510VE Service panel KTBJ25K56F KTBJ25K80F KTBJ25K160F Air discharge adaptor KDAJ25K56A KDAJ25K71A KDAJ25K140A Adaptor for wiring (operation status output) BRP11B62 Wiring adaptor for electrical appendices (1) KRP2A61 Wiring adaptor for electrical appendices (2) KRP4AA51 Installation box for adaptor PCB *1 KRP4A96 *2, 3 External control adaptor for outdoor unit DTA104A61 Adaptor for multi tenant (24V type) DTA114A61 Digital input adaptor for hotel application BRP7A53 Notes: *1. Installation Box ☆ is necessary for each adaptor marked ★. *2. Up to 2 adaptors can be fixed for each installation box. *3. Only one installation box can be installed for each indoor unit. *4. Remote sensor is necessary when using wireless remote controller. tnempiuqE tnemtaerT riA Air Treatment Equipment