Back to resultsSpecification results
Daikin FXNQ-MA — representative product image
Representative image · Vietnamese catalogue, PDF 219 ↗
Indoor unitFXNQ-MA →

FXNQ63MAVE

Daikin · Concealed floor standing

FXNQ63MAVE is a Daikin indoor unit in the FXNQ-MA series, concealed floor standing type. Its rated cooling capacity is 7.1 kW according to catalogue PCVVN2507Aaprv.

Rated cooling capacity
7.1 kW
Power supply
1-phase, 220-240 V/220 V, 50/60 Hz
Dimensions (H×W×D)
610×1,350×220 mm
Weight
29 kg
Data extracted from the English catalogue; not all specifications have been manually verified. Check the source before use. Source & notes →
Open comparison tool →

FXNQ63MAVE specifications

FXNQ63MAVE specifications · PCVVN2507Aaprv
Rated capacity 4 specifications
Cooling capacity · Btu/h24,200
Cooling capacity · kW7.1
Heating capacity · Btu/h27,300
Heating capacity · kW8.0
Electrical & efficiency 3 specifications
Power supply1-phase, 220-240 V/220 V, 50/60 Hz
Power consumption · Cooling · kW0.110
Power consumption · Heating · kW0.110
Airflow & sound 4 specifications
Airflow rate (H/L) · m3/min16/12
Airflow rate (H/L) · cfm565/424
Sound level (H/L) · 220 V · dB(A)43/38
Sound level (H/L) · 240 V · dB(A)45/39
Dimensions & weight 3 specifications
CasingGalvanised steel plate
Dimensions (H × W × D) · mm610×1,350×220
Machine weight · kg29
Piping & refrigerant 3 specifications
Piping connections · Liquid (Flare) · mm9.5
Piping connections · Gas (Flare) · mm15.9
Piping connections · Drain · mm21O.D.

Catalogue source & rating conditions

Values are taken from PCVVN2507Aaprv, PDF page 219 (printed page 218). General Catalogue 2025; published on VRV.vn as Catalogue 2026 (EN).

Rated performance depends on test conditions and system combinations. Check the source notes when selecting equipment or comparing series.

Read original source notes (English)
Notes: Specifications are based on the following conditions; • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Height difference: 0 m. • Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Height difference: 0 m. • Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) • Sound level: Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m. During actual operation, these values are normally somewhat higher as a result of ambient conditions. 218 stinU roodnI
View catalogue page · PDF 219

The original page preserves symbols, merged cells and accessories; not every accessory shown is supplied with the unit.

Original English catalogue, PDF page 219
Read all text from this page and its facing page
PDF page 219 VRV Indoor Units Concealed Floor Standing Type FXNQ-MA Designed to be concealed in the perimeter skirting-wall • The unit is concealed in skirting-wall of perimeter, that enables to create high class interior design. • The connecting port faces downward, greatly facilitating on-site piping work. • A long-life filter (maintenance free up to one year*) is equipped as standard accessory. *8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3 Specifications MODEL FXNQ20MAVE FXNQ25MAVE FXNQ32MAVE FXNQ40MAVE FXNQ50MAVE FXNQ63MAVE Power supply 1-phase, 220-240 V/220 V, 50/60 Hz Btu/h 7,500 9,600 12,300 15,400 19,100 24,200 Cooling capacity kW 2.2 2.8 3.6 4.5 5.6 7.1 Btu/h 8,500 10,900 13,600 17,100 21,500 27,300 Heating capacity kW 2.5 3.2 4.0 5.0 6.3 8.0 Power Cooling 0.049 0.090 0.110 kW consumption Heating 0.049 0.090 0.110 Casing Galvanised steel plate m3/min 7/6 8/6 11/8.5 14/11 16/12 Airflow rate (H/L) cfm 247/212 282/212 388/300 494/388 565/424 220 V 38/35 41/36 42/37 43/38 Sound level (H/L) dB(A) 240 V 39/36 43/37 44/38 45/39 Dimensions (H × W × D) mm 610×930×220 610×1,070×220 610×1,350×220 Machine weight kg 19 24 29 Liquid (Flare) 6.4 9.5 Piping Gas (Flare) mm 12.7 15.9 connections Drain 21O.D. Notes: Specifications are based on the following conditions; • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Height difference: 0 m. • Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Height difference: 0 m. • Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) • Sound level: Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m. During actual operation, these values are normally somewhat higher as a result of ambient conditions. 218 stinU roodnI FACING PAGE — PDF page 218 Floor Standing Type FXLQ-MA Suitable for perimeter zone air conditioning • Floor Standing types can be hung on the wall for easier cleaning. Running the piping from the back allows the unit to be hung on walls. Cleaning under the unit, where dust tends to accumulate, is considerably easier. • The adoption of a fibre-less discharge grille featuring an original design to prevent condensation also helps prevent staining and makes cleaning easier. • A long-life filter (maintenance free up to one year*) is equipped as standard accessory. *8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3 Specifications MODEL FXLQ20MAVE FXLQ25MAVE FXLQ32MAVE FXLQ40MAVE FXLQ50MAVE FXLQ63MAVE Power supply 1-phase, 220-240 V/220 V, 50/60 Hz Btu/h 7,500 9,600 12,300 15,400 19,100 24,200 Cooling capacity kW 2.2 2.8 3.6 4.5 5.6 7.1 Btu/h 8,500 10,900 13,600 17,100 21,500 27,300 Heating capacity kW 2.5 3.2 4.0 5.0 6.3 8.0 Power Cooling 0.049 0.090 0.110 kW consumption Heating 0.049 0.090 0.110 Casing Ivory white (5Y7.5/1) m3/min 7/6 8/6 11/8.5 14/11 16/12 Airflow rate (H/L) cfm 247/212 282/212 388/300 494/388 565/424 220 V 38/35 41/36 42/37 43/38 Sound level (H/L) dB(A) 240 V 39/36 43/37 44/38 45/39 Dimensions (H × W × D) mm 600×1,000×222 600×1,140×222 600×1,420×222 Machine weight kg 25 30 36 Liquid (Flare) 6.4 9.5 Piping Gas (Flare) mm 12.7 15.9 connections Drain 21O.D. Notes: Specifications are based on the following conditions; • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Height difference: 0 m. • Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Height difference: 0 m. • Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) • Sound level: Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m. During actual operation, these values are normally somewhat higher as a result of ambient conditions. 217

Catalogue article on VRV.vn ↗ · Original English PDF on VRV.vn ↗