FXNQ32MAVE is a Daikin indoor unit in the FXNQ-MA series, concealed floor standing type. Its rated cooling capacity is 3.6 kW according to catalogue PCVVN2507Aaprv.
- Rated cooling capacity
- 3.6 kW
- Power supply
- 1-phase, 220-240 V/220 V, 50/60 Hz
- Dimensions (H×W×D)
- 610×1,070×220 mm
- Weight
- 24 kg
Data extracted from the English catalogue; not all specifications have been manually verified. Check the source before use. Source & notes →
FXNQ32MAVE specifications
| Rated capacity 4 specifications | |
|---|---|
| Cooling capacity · Btu/h | 12,300 |
| Cooling capacity · kW | 3.6 |
| Heating capacity · Btu/h | 13,600 |
| Heating capacity · kW | 4.0 |
| Electrical & efficiency 3 specifications | |
| Power supply | 1-phase, 220-240 V/220 V, 50/60 Hz |
| Power consumption · Cooling · kW | 0.090 |
| Power consumption · Heating · kW | 0.090 |
| Airflow & sound 4 specifications | |
| Airflow rate (H/L) · m3/min | 8/6 |
| Airflow rate (H/L) · cfm | 282/212 |
| Sound level (H/L) · 220 V · dB(A) | 38/35 |
| Sound level (H/L) · 240 V · dB(A) | 39/36 |
| Dimensions & weight 3 specifications | |
| Casing | Galvanised steel plate |
| Dimensions (H × W × D) · mm | 610×1,070×220 |
| Machine weight · kg | 24 |
| Piping & refrigerant 3 specifications | |
| Piping connections · Liquid (Flare) · mm | 6.4 |
| Piping connections · Gas (Flare) · mm | 12.7 |
| Piping connections · Drain · mm | 21O.D. |
No matching specifications. Try another search term.
Catalogue source & rating conditions
Values are taken from PCVVN2507Aaprv, PDF page 219 (printed page 218). General Catalogue 2025; published on VRV.vn as Catalogue 2026 (EN).
Rated performance depends on test conditions and system combinations. Check the source notes when selecting equipment or comparing series.
Read original source notes (English)
Notes: Specifications are based on the following conditions;
• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Height difference: 0 m.
• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Height difference: 0 m.
• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
• Sound level: Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
218
stinU
roodnI
View catalogue page · PDF 219
The original page preserves symbols, merged cells and accessories; not every accessory shown is supplied with the unit.

Read all text from this page and its facing page
PDF page 219
VRV Indoor Units
Concealed Floor Standing Type
FXNQ-MA
Designed to be concealed in the perimeter skirting-wall
• The unit is concealed in skirting-wall of perimeter, that enables to create high class interior design.
• The connecting port faces downward, greatly facilitating on-site piping work.
• A long-life filter (maintenance free up to one year*) is equipped as standard accessory.
*8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3
Specifications
MODEL FXNQ20MAVE FXNQ25MAVE FXNQ32MAVE FXNQ40MAVE FXNQ50MAVE FXNQ63MAVE
Power supply 1-phase, 220-240 V/220 V, 50/60 Hz
Btu/h 7,500 9,600 12,300 15,400 19,100 24,200
Cooling capacity
kW 2.2 2.8 3.6 4.5 5.6 7.1
Btu/h 8,500 10,900 13,600 17,100 21,500 27,300
Heating capacity
kW 2.5 3.2 4.0 5.0 6.3 8.0
Power Cooling 0.049 0.090 0.110
kW
consumption Heating 0.049 0.090 0.110
Casing Galvanised steel plate
m3/min 7/6 8/6 11/8.5 14/11 16/12
Airflow rate (H/L)
cfm 247/212 282/212 388/300 494/388 565/424
220 V 38/35 41/36 42/37 43/38
Sound level (H/L) dB(A)
240 V 39/36 43/37 44/38 45/39
Dimensions (H × W × D) mm 610×930×220 610×1,070×220 610×1,350×220
Machine weight kg 19 24 29
Liquid (Flare) 6.4 9.5
Piping Gas (Flare) mm 12.7 15.9
connections
Drain 21O.D.
Notes: Specifications are based on the following conditions;
• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Height difference: 0 m.
• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Height difference: 0 m.
• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
• Sound level: Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
218
stinU
roodnI
FACING PAGE — PDF page 218
Floor Standing Type
FXLQ-MA
Suitable for perimeter zone air conditioning
• Floor Standing types can be hung on the wall for easier cleaning. Running the piping from the back
allows the unit to be hung on walls. Cleaning under the unit, where dust tends to accumulate, is
considerably easier.
• The adoption of a fibre-less discharge grille featuring an original design to prevent condensation also
helps prevent staining and makes cleaning easier.
• A long-life filter (maintenance free up to one year*) is equipped as standard accessory.
*8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3
Specifications
MODEL FXLQ20MAVE FXLQ25MAVE FXLQ32MAVE FXLQ40MAVE FXLQ50MAVE FXLQ63MAVE
Power supply 1-phase, 220-240 V/220 V, 50/60 Hz
Btu/h 7,500 9,600 12,300 15,400 19,100 24,200
Cooling capacity
kW 2.2 2.8 3.6 4.5 5.6 7.1
Btu/h 8,500 10,900 13,600 17,100 21,500 27,300
Heating capacity
kW 2.5 3.2 4.0 5.0 6.3 8.0
Power Cooling 0.049 0.090 0.110
kW
consumption Heating 0.049 0.090 0.110
Casing Ivory white (5Y7.5/1)
m3/min 7/6 8/6 11/8.5 14/11 16/12
Airflow rate (H/L)
cfm 247/212 282/212 388/300 494/388 565/424
220 V 38/35 41/36 42/37 43/38
Sound level (H/L) dB(A)
240 V 39/36 43/37 44/38 45/39
Dimensions (H × W × D) mm 600×1,000×222 600×1,140×222 600×1,420×222
Machine weight kg 25 30 36
Liquid (Flare) 6.4 9.5
Piping Gas (Flare) mm 12.7 15.9
connections
Drain 21O.D.
Notes: Specifications are based on the following conditions;
• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Height difference: 0 m.
• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Height difference: 0 m.
• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
• Sound level: Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
217
Catalogue article on VRV.vn ↗ · Original English PDF on VRV.vn ↗