FXBPQ63PVE is a Daikin indoor unit in the FXB(P)Q-P series, cleanroom air conditioner type. Its rated cooling capacity is 7.1 kW according to catalogue PCVVN2507Aaprv.
- Rated cooling capacity
- 7.1 kW
- Power supply
- 1-phase, 220-240 V/220 V, 50/60 Hz
- Dimensions (H×W×D)
- 492×1,078×1,300 mm
- Weight
- See specifications
Data extracted from the English catalogue; not all specifications have been manually verified. Check the source before use. Source & notes →
FXBPQ63PVE specifications
| Rated capacity 4 specifications | |
|---|---|
| Cooling capacity · Btu/h | 24,200 |
| Cooling capacity · kW | 7.1 |
| Heating capacity · Btu/h | 27,300 |
| Heating capacity · kW | 8.0 |
| Electrical & efficiency 3 specifications | |
| Power supply | 1-phase, 220-240 V/220 V, 50/60 Hz |
| Power consumption · Cooling · kW | 0.45 |
| Power consumption · Heating · kW | 0.45 |
| Airflow & sound 3 specifications | |
| Airflow rate (H/L) · m3/min | 26/22.5 |
| Airflow rate (H/L) · cfm | 918/794 |
| Sound level (H/L) *4 · dB(A) | 44/42 |
| Dimensions & weight 3 specifications | |
| Indoor unit weight · kg | 120 *6 |
| Casing | Galvanised steel plate |
| Dimensions (H×W×D) · mm | 492×1,078×1,300 |
| Piping & refrigerant 3 specifications | |
| Piping connections · Liquid (Flare) · mm | 9.5 |
| Piping connections · Gas (Flare) · mm | 15.9 |
| Piping connections · Drain · mm | PT1B |
| Filters 3 specifications | |
| Intake filter efficiency *1 | 70% by gravimetric method |
| Outlet HEPA filter efficiency *2 | 99.97% by DOP method *5 |
| Filter(Option) · HEPA filter · Model | BAFH82A63 |
| Controls & accessories 4 specifications | |
| MODEL · Outlet unit | BAF82A63 |
| Outlet unit weight · kg | 65 *3 |
| Panel (Option) · Ceiling intake type · Model | BYB82A63CP |
| Panel (Option) · Floor-level intake type · Model | BYB82A63WP |
No matching specifications. Try another search term.
Catalogue source & rating conditions
Values are taken from PCVVN2507Aaprv, PDF page 223 (printed page 222). General Catalogue 2025; published on VRV.vn as Catalogue 2026 (EN).
Rated performance depends on test conditions and system combinations. Check the source notes when selecting equipment or comparing series.
Read original source notes (English)
Notes: Specifications are based on the following conditions;
• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Height difference: 0 m.
• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Height difference: 0 m.
• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
*1: An intake air filter is only attached to the ceiling intake type.
*2: HEPA filter sold separately. The dust collection efficiency of HEPA filter is 99.97%. However, air may slightly leak around the filter when installing.
*3: Weight including HEPA filter and panel.
*4: Anechoic chamber conversion value under JIS B 8616 test conditions. Value usually increases slightly in practice due to surrounding conditions.
*5: The clean room air conditioner does not support DOP testing (leak test) based on GMP standards
(Standards for Manufacturing Control and Quality Control for Medical Devices ) due to slight leakage at time of product installation.
*6: Weight including panel.
*In the case of an installation in an operating theatre etc. where an air conditioner malfunction may have serious consequences, please build
in redundancy with two or more outdoor units.
Because the ceiling intake type provides concentrated air conditioning that blows directly under the outlet. Use the floor-level intake type in
Accordingly, please be aware of the following. the following kind of locations.
Warning • Sufficient heating may not be achieved near the floor or at locations far from the outlet. • Locations in which heating of
• In the case of utilization in a hospital, some patients may be susceptible to cool drafts, so please ensure that they do not come directly under the outlet. the lower part or the entire
• Install multiple units using two or more outdoor unit systems for installations to rooms such as operating rooms where the failure of the air room is important.
conditioner may have serious consequences. • Locations necessitating a
• In order to maintain static pressure in a room, the indoor fan continues to operate even when an abnormality occurs due to the thermostat shutting particularly high cleanliness
off, defrost operation, protection device operation, or similar issue. factor and in which there are
• When incorporating outdoor air from the fresh air intake, install a damper or similar device to the duct routing and have it interlocked with the indoor many people.
fan so that the outdoor air is shut out when the fan stops.
The air that incorporates the suction filter may flow backward and allow dust trapped in the filter to return to the room.
• When using gas to disinfect hospital operating rooms where this unit is installed, stop operation and cover the air inlet and outlet with plastic sheets
to prevent the gas from reaching and damaging the air conditioner.
222
stinU
roodnI
View catalogue page · PDF 223
The original page preserves symbols, merged cells and accessories; not every accessory shown is supplied with the unit.

Read all text from this page and its facing page
PDF page 223
VRV Indoor Units
Antibacterial
Suppresses the propagation of bacteria in the duct with a proprietary antibacterial coating
The filter implements an antibacterial treatment with a new coating combining a silver-based inorganic
antibacterial material (an organic antibacterial material that is effective against germs) that prevents
mould.
This enhances the antibacterial properties of the duct.
An antibacterial treatment using a silver-based organic substance reduces mould.
Antibacterial fiber used in the intake filter Fan Intake filter
With a long-life filter employing anti-mould antibacterial fiber
near the intake, cleaning performance is further enhanced.
* Please be aware that antibacterial products suppress the propagation of bacteria but do not have a
sterilizing effect. Also, mould may grow in places where dust or soot accumulates.
* A material for which the registered safety was verified by Japanese chemicals and dangerous
substances regulation law (Act on the Evaluation of Chemical Substances and Regulation of Their Outlet panel HEPA filter Sheet steel Intake panel
Manufacture, etc) is used for the antibacterial material. (punching metal) drain pan (punching metal)
* Periodic maintenance is required (such as cleaning the air filter and washing the inside to the unit). (antibacterial treated)
Specifications
Type Integrated outlet unit model Separate outlet unit model
Indoor unit FXBQ40PVE FXBQ50PVE FXBQ63PVE FXBPQ63PVE
MODEL
Outlet unit Integrated with the indoor unit BAF82A63
Power supply 1-phase, 220-240 V/220 V, 50/60 Hz
Btu/h 15,400 19,100 24,200
Cooling capacity
kW 4.5 5.6 7.1
Btu/h 17,100 21,500 27,300
Heating capacity
kW 5.0 6.3 8.0
Cooling 0.31 0.45
Power consumption kW
Heating 0.31 0.45
Intake filter efficiency *1 70% by gravimetric method
Outlet HEPA filter efficiency *2 99.97% by DOP method *5
Indoor unit weight kg 140 *3 185 *3 120 *6
Casing Galvanised steel plate
m3/min 19.5/17.5 26/22.5
Airflow rate (H/L)
cfm 688/618 918/794
Sound level (H/L) *4 dB(A) 44/42
Dimensions (H×W×D) mm 492×1,788×1,000 492×1,788×1,300 492×1,078×1,300
Outlet unit weight kg – 65 *3
Liquid (Flare) 6.4 9.5
Piping
Gas (Flare) mm 12.7 15.9
connections
Drain PT1B
Filter(Option) HEPA filter BAFH82A50 BAFH82A63
Panel Ceiling intake type Model BYB82A50C BYB82A63C BYB82A63CP
(Option) Floor-level intake type BYB82A50W BYB82A63W BYB82A63WP
Notes: Specifications are based on the following conditions;
• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Height difference: 0 m.
• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Height difference: 0 m.
• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
*1: An intake air filter is only attached to the ceiling intake type.
*2: HEPA filter sold separately. The dust collection efficiency of HEPA filter is 99.97%. However, air may slightly leak around the filter when installing.
*3: Weight including HEPA filter and panel.
*4: Anechoic chamber conversion value under JIS B 8616 test conditions. Value usually increases slightly in practice due to surrounding conditions.
*5: The clean room air conditioner does not support DOP testing (leak test) based on GMP standards
(Standards for Manufacturing Control and Quality Control for Medical Devices ) due to slight leakage at time of product installation.
*6: Weight including panel.
*In the case of an installation in an operating theatre etc. where an air conditioner malfunction may have serious consequences, please build
in redundancy with two or more outdoor units.
Because the ceiling intake type provides concentrated air conditioning that blows directly under the outlet. Use the floor-level intake type in
Accordingly, please be aware of the following. the following kind of locations.
Warning • Sufficient heating may not be achieved near the floor or at locations far from the outlet. • Locations in which heating of
• In the case of utilization in a hospital, some patients may be susceptible to cool drafts, so please ensure that they do not come directly under the outlet. the lower part or the entire
• Install multiple units using two or more outdoor unit systems for installations to rooms such as operating rooms where the failure of the air room is important.
conditioner may have serious consequences. • Locations necessitating a
• In order to maintain static pressure in a room, the indoor fan continues to operate even when an abnormality occurs due to the thermostat shutting particularly high cleanliness
off, defrost operation, protection device operation, or similar issue. factor and in which there are
• When incorporating outdoor air from the fresh air intake, install a damper or similar device to the duct routing and have it interlocked with the indoor many people.
fan so that the outdoor air is shut out when the fan stops.
The air that incorporates the suction filter may flow backward and allow dust trapped in the filter to return to the room.
• When using gas to disinfect hospital operating rooms where this unit is installed, stop operation and cover the air inlet and outlet with plastic sheets
to prevent the gas from reaching and damaging the air conditioner.
222
stinU
roodnI
FACING PAGE — PDF page 222
Clean Room Air Conditioner
FXB(P)Q-P
Suitable for hospitals and other clean spaces
Easily provides the high Select the air flow system and
cleanliness environment installation method to match the
required by various industries layout and purpose of the room
Daikin’s clean room air conditioners are specially Two types of clean room air conditioners are
designed to achieve an environment cleanliness available – an integrated unit model and a
class 10,000. These air conditioners easily realize a separate outlet unit model.
cleanliness-class environment and help create a It is also possible to configure the air flow system
proper environment of hospitals, food and to ceiling intake or floor-level intake according to
beverage factories, electronics factories, and other the panel selected.
spaces that require clean air. This flexible design enables the air conditioner to
easily adopt to any room layout or use.
Instances of installation by type (for a hospital)
Ceiling intake type Floor-level intake type
Type
(high speed contracted flow/high ceiling model) (gentle wind distribution/high cleanness class model)
Easy to increase the cleanness and air-conditioning effect.
Construction work is simple and a ceiling installation is possible.
Features A low flow speed prevents drying of the affected part
Dust filtering and air-conditioning can be started immediately.
and the experience of drafts.
Cleanness class*1 100,000 to 10,000 10,000
Wind speed 1.0 m/s or higher Approximately 0.5 m/s
• Concentrated air conditioning centered directly under the unit • Total air conditioning with an emphasis on cleanliness
• Easy installation
Integrated
outlet unit Intake
(sourced locally)
model
Blow Applications: Surgery prep rooms, recovery rooms, nurse stations, etc. Applications: Operating theatres, delivery rooms, etc.
method
• Somewhat concentrated air conditioning centered • Total air conditioning with an emphasis on cleanliness
directly under the outlet • Maintenance possible from a different room
• Can provide air conditioning
Separate in rooms with irregular shapes
Outlet Air
outlet unit unit conditioner Intake
model (sourced locally)
Applications: CCU*2, sterile rooms, etc. Applications: Premature nurseries, newborn nurseries, ICU*3, etc.
* 1. Cleanliness class. A scale expressing the cleanliness of air established by NASA (National Aeronautics and Space Administration). Class 10,000 represents a state
of less than 10,000 minute particles of diameter under 0.5 μm per cubic foot. For comparison, the cleanliness of a typical office is around class 1,000,000.
* 2. CCU (Cardiac Care Unit). A ward dedicated to the admission of patients with myocardial infarctions and other heart diseases.
* 3. ICU (Intensive Care Unit). A ward for the careful treatment and nursing of patients with serious illnesses, injuries, or recovering from operations.
Prevents uncomfortable drafts with a low flow speed of
approximately 0.5 m/s
The floor-level intake system has a low flow speed of approximately 0.5 m/s.
Filtration
Class 10,000 clean room condition achieved with a HEPA filter (sold separately)
The low pressure-loss HEPA filter (sold separately) demonstrates superior dust filtering performance and
easily accomplishes an air cleanliness of class 10,000.
* It may not be possible to maintain cleanliness in rooms with low air tightness.
221
Catalogue article on VRV.vn ↗ · Original English PDF on VRV.vn ↗