RZUR200QY1

Daikin · Cooling only · Inverter air cooled Packaged · R-410A

RZUR200QY1 is a Daikin outdoor unit in the RZUR-Q · Packaged series, cooling only · inverter air cooled packaged · r-410a type. Its reference system cooling capacity (*1) is 23.5 kW according to catalogue PCTPMT2309.

Reference system cooling capacity
23.5 kW
Power supply
3 Phase, 380–415 V, 50 Hz
Dimensions (H×W×D)
870×1,100×460 mm
Weight
113 kg
Data extracted from the English catalogue; not all specifications have been manually verified. Check the source before use. Source & notes →
Open comparison tool →

RZUR200QY1 specifications

RZUR200QY1 specifications · PCTPMT2309
System configuration 1 specifications
Unit combinationFDR200QY1 + RZUR200QY1
Rated capacity 5 specifications
Cooling capacity (19.5°CWB) *1 *3 · kW23.50
Cooling capacity (19.5°CWB) *1 *3 (Max.) · kW23.50 (23.74)
Cooling capacity (19.5°CWB) *1 *3 (Max.) · Btu/h80,000 (81,000)
Cooling capacity (19°CWB) *2 *3 (Max.) · kW23.20 (23.50)
Cooling capacity (19°CWB) *2 *3 (Max.) · Btu/h79,000 (80,000)
Electrical & efficiency 6 specifications
System power consumption (19.5°CWB) *1 *3 · kW8.97
System power consumption (19°CWB) *2 *3 · kW8.92
CSPF (19°CWB) *24.30
Power supply3 Phase, 380–415 V, 50 Hz
Compressor · TypeHermetically sealed swing type
Compressor · Motor output · kW3.2×1
Airflow & sound 2 specifications
Air flow rate (H) · m³/min126
Sound level *4 · dB(A)61
Dimensions & weight 3 specifications
Casing colourIvory White
Dimensions (H×W×D) · mm870×1,100×460
Machine weight · kg113
Piping & refrigerant 6 specifications
Refrigerant · TypeR-410A
Refrigerant charge · kg3.8
Refrigerant piping · Liquid · mmØ 9.5 (Brazing)
Refrigerant piping · Gas · mmØ 19.1 (Brazing)
Max. piping length · m70 (equivalent length 90 m)
Max. level difference · m50 *6
Operating conditions 1 specifications
Operation range · °CDB10 to 49

Catalogue source & rating conditions

Values are taken from PCTPMT2309, PDF page 4 (printed page 6). Daikin Inverter Air Cooled Packaged · PCTPMT2309.

Rated performance depends on test conditions and system combinations. Check the source notes when selecting equipment or comparing series.

Read original source notes (English)
Note: *1. Indoor temp.: 27°CDB, 19.5°CWB / outdoor temp.: 35°CDB, 24°CWB / Equivalent piping length: 7.5 m, level difference: 0 m. *2. Indoor temp.: 27°CDB, 19°CWB / outdoor temp.: 35°CDB, 24°CWB / Equivalent piping length: 7.5 m, level difference: 0 m. *3. Capacity is net, including a deduction for cooling for indoor fan motor heat. *4. Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation these values are normally somewhat higher as a result of ambient conditions and oil recovery mode. Consider location and soundproofing measures near residences. *5. The value is the external static pressure with standard pulley. *6. Max. 40 m if the outdoor unit is lower than the indoor unit. Packaged system: cooling capacity, system power consumption and CSPF refer to the stated indoor/outdoor pairing. Outdoor model pages use the FDR pairing as the reference, except the RZUR-P models, which use their respective FVGR-P pairings. Parenthetical capacities are the source maximum values. Optional equipment is shown separately in the PDF.
View catalogue page · PDF 4

The original page preserves symbols, merged cells and accessories; not every accessory shown is supplied with the unit.

Original English catalogue, PDF page 4
Read all text from this page and its facing page
Note: *1. Indoor temp.: 27°CDB, 19.5°CWB / outdoor temp.: 35°CDB, 24°CWB / Equivalent piping length: 7.5 m, level difference: 0 m. *2. Indoor temp.: 27°CDB, 19°CWB / outdoor temp.: 35°CDB, 24°CWB / Equivalent piping length: 7.5 m, level difference: 0 m. *3. Capacity is net, including a deduction for cooling for indoor fan motor heat. *4. Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation these values are normally somewhat higher as a result of ambient conditions and oil recovery mode. Consider location and soundproofing measures near residences. *5. The value is the external static pressure with standard pulley. *6. Max. 40 m if the outdoor unit is lower than the indoor unit. Packaged system: cooling capacity, system power consumption and CSPF refer to the stated indoor/outdoor pairing. Outdoor model pages use the FDR pairing as the reference, except the RZUR-P models, which use their respective FVGR-P pairings. Parenthetical capacities are the source maximum values. Optional equipment is shown separately in the PDF.