FXFTQ125AVM is a Daikin indoor unit in the FXFTQ-A / FXFSQ-C series, cassette round flow with sensor and streamer type. Its rated cooling capacity is 14 kW according to catalogue PCVVN2507Aaprv.
- Rated cooling capacity
- 14 kW
- Power supply
- 1-phase, 220-240 V/220-230 V, 50/60 Hz
- Dimensions (H×W×D)
- 298×840×840 mm
- Weight
- 25 kg
Data extracted from the English catalogue; not all specifications have been manually verified. Check the source before use. Source & notes →
FXFTQ125AVM specifications
| Rated capacity 4 specifications | |
|---|---|
| Cooling capacity · Btu/h | 47,800 |
| Cooling capacity · kW | 14.0 |
| Heating capacity · Btu/h | 54,600 |
| Heating capacity · kW | 16.0 |
| Electrical & efficiency 3 specifications | |
| Power supply | 1-phase, 220-240 V/220-230 V, 50/60 Hz |
| Power consumption · Cooling · kW | 0.170 |
| Power consumption · Heating · kW | 0.159 |
| Airflow & sound 3 specifications | |
| Airflow rate (H/HM/M/ML/L) · m3/min | 34.5/31.5/28.5/25.5/23 |
| Airflow rate (H/HM/M/ML/L) · cfm | 1,218/1,112/1,006/900/812 |
| Sound level (H/HM/M/ML/L) · dB(A) | 45/42.5/39.5/37/35 |
| Dimensions & weight 3 specifications | |
| Casing | Galvanised steel plate |
| Dimensions (H×W×D) · mm | 298×840×840 |
| Machine weight · kg | 25 |
| Piping & refrigerant 3 specifications | |
| Piping connections · Liquid (Flare) · mm | 9.5 |
| Piping connections · Gas (Flare) · mm | 15.9 |
| Piping connections · Drain · mm | VP25 (External Dia. 32/Internal Dia. 25) |
No matching specifications. Try another search term.
Catalogue source & rating conditions
Values are taken from PCVVN2507Aaprv, PDF page 185 (printed page 184). General Catalogue 2025; published on VRV.vn as Catalogue 2026 (EN).
Rated performance depends on test conditions and system combinations. Check the source notes when selecting equipment or comparing series.
Read original source notes (English)
Notes: Specifications are based on the following conditions;
• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Height difference: 0 m.
• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Height difference: 0 m.
• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
• Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Panel (Option) Function List
Model BYCQ125EEF (Fresh White) Wired Wireless
Dimensions(H×W×D) mm 50×950×950 Remote controller FXFTQ-A FXFSQ-C FXFSQ-C
Standard
panel Weight kg 5.5 BRC1H63W(K) BRC1H63W(K) BRC1E63 BRC7M635F(K) / BRC7M634F(K)
with Model BYCQ125EEK (Black) Streamer function unit
sensing
Dimensions(H×W×D) mm 50×950×950 Dual sensors *1
Weight kg 5.5 Auto airflow function (Direct airflow) *1
Auto airflow function (Draft prevention) *1
Sensing sensor low mode *1
Sensing sensor stop mode *1
Circulation airflow *2
Individual airflow direction control
Switchable 5 step fan speed
Auto airflow rate
Auto swing
Selectable airflow pattern *1
High ceiling application
*1. Applicable when sensing panel is installed.
*2. Refer to Circulation airflow on page 189 for details.
184
stinU
roodnI
View catalogue page · PDF 185
The original page preserves symbols, merged cells and accessories; not every accessory shown is supplied with the unit.

Read all text from this page and its facing page
PDF page 185
VRV Indoor Units
Specifications
MODEL FXFTQ25AVM FXFTQ32AVM FXFTQ40AVM FXFTQ50AVM FXFTQ63AVM FXFTQ80AVM FXFTQ100AVM FXFTQ125AVM FXFTQ140AVM
Power supply 1-phase, 220-240 V/220-230 V, 50/60 Hz
Btu/h 9,600 12,300 15,400 19,100 24,200 30,700 38,200 47,800 54,600
Cooling capacity
kW 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.0 16.0
Btu/h 10,900 13,600 17,100 21,500 27,300 34,100 42,700 54,600
Heating capacity
kW 3.2 4.0 5.0 6.3 8.0 10.0 12.5 16.0
Cooling 0.028 0.035 0.056 0.061 0.092 0.164 0.170 0.194
Power consumption kW
Heating 0.026 0.034 0.056 0.060 0.092 0.144 0.159 0.183
Casing Galvanised steel plate
m3/min 13/12.5/11.5/11/10 17/13.5/12.5/12/11 23/20.5/19/14.5/11 23.5/21/20/16/13.5 24.5/22/20.5/20/15 33.5/30.5/27/23.5/2134.5/31.5/28.5/25.5/2335.5/32.5/29.5/26.5/23
Airflow rate (H/HM/M/ML/L)
cfm 459/441/406/388/353 600/477/441/424/388 812/724/671/512/388 830/741/706/565/477 865/777/724/706/530 1,183/1,077/953/830/7411,218/1,112/1,006/900/8121,253/1,147/1,041/935/812
Sound level (H/HM/M/ML/L) dB(A) 30/29.5/28.5/28/27 35/29.5/29/28/27 38/35/34.5/29.5/27 38/36/35.5/31.5/28 39/37/36/35.5/31 44/41/38/35/33 45/42.5/39.5/37/3546/43.5/40.5/38/35
Dimensions (H×W×D) mm 256×840×840 298×840×840
Machine weight kg 19 24 22 25 26
Liquid (Flare) 6.4 9.5
Piping
connections Gas (Flare) mm 12.7 15.9
Drain VP25 (External Dia. 32/Internal Dia. 25)
MODEL FXFSQ25CVM FXFSQ50CVM
Power supply 1-phase, 220-240 V/220-230 V, 50/60 Hz
Btu/h 9,600 19,100
Cooling capacity
kW 2.8 5.6
Btu/h 10,900 21,500
Heating capacity
kW 3.2 6.3
Cooling 0.035 0.056
Power consumption kW
Heating 0.035 0.056
Casing Galvanised steel plate
m3/min 19/15.5/14.5/12.5/11 28.5/27/25.5/24/23
Airflow rate (H/HM/M/ML/L)
cfm 671/547/512/441/388 1,006/953/900/847/812
Sound level (H/HM/M/ML/L) dB(A) 34.5/32/29.5/28.5/27 39.5/38.0/37.0/36.0/35.0
Dimensions (H×W×D) mm 256×840×840 298×840×840
Machine weight kg 24 25
Liquid 6.4
Piping
connections Gas mm 12.7
Drain VP25 (External dia. 32/Internal dia. 25)
Notes: Specifications are based on the following conditions;
• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Height difference: 0 m.
• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Height difference: 0 m.
• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
• Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Panel (Option) Function List
Model BYCQ125EEF (Fresh White) Wired Wireless
Dimensions(H×W×D) mm 50×950×950 Remote controller FXFTQ-A FXFSQ-C FXFSQ-C
Standard
panel Weight kg 5.5 BRC1H63W(K) BRC1H63W(K) BRC1E63 BRC7M635F(K) / BRC7M634F(K)
with Model BYCQ125EEK (Black) Streamer function unit
sensing
Dimensions(H×W×D) mm 50×950×950 Dual sensors *1
Weight kg 5.5 Auto airflow function (Direct airflow) *1
Auto airflow function (Draft prevention) *1
Sensing sensor low mode *1
Sensing sensor stop mode *1
Circulation airflow *2
Individual airflow direction control
Switchable 5 step fan speed
Auto airflow rate
Auto swing
Selectable airflow pattern *1
High ceiling application
*1. Applicable when sensing panel is installed.
*2. Refer to Circulation airflow on page 189 for details.
184
stinU
roodnI
FACING PAGE — PDF page 184
Round Flow Cassette with Sensing and Streamer Type
Other functions
Quick and easy installation
Installable in tight ceiling spaces 850 mm
Min. of 261 mm* ceiling space when using standard panel. 175 mm
* For FXFTQ25-80A models.
Drain pump is equipped as standard accessory with 850 mm lift.
Easy maintenance
Just open the suction grille!
Drain pan and drain water check
Drain outlet
The condition of the drain pan and drain water can be (with rubber plug)
checked by removing the suction grille and drain plug.
Note: For inquiries concerning auto
grille panel installations, please
contact your local dealer or
Daikin representative.
Cleanliness
Silver ion anti-bacterial drain pan
Prevents the growth of slime, bacteria, and mould that cause odours and clogging.
* Drain pan should be changed once every two to three years.
Filter has anti-mould and antibacterial treatment
BAF552A160
High Performance Prefilter (MERV 8) (Option) See page 296
This filter can catch more harmful substances in the air such as PM2.5.
UV Streamer air purifier unit (Option for FXFSQ-C only) See page 5 - 6
Adopts “deep ultraviolet (UVC) LED” which irradiates deep ultraviolet rays
with a wavelengths of around 265 nm that have a high sterilizing effect.
Antibacterial /
Antiviral filter
MERV 13 rating
Promotion
Movie BAEF125AW1
Panel (Option)
Standard panel with sensing Standard panel with sensing
183 BYCQ125EEF (Fresh White) BYCQ125EEK (Black)
Catalogue article on VRV.vn ↗ · Original English PDF on VRV.vn ↗