Back to resultsSpecification results
Daikin FXEQ-A — representative product image
Representative image · Vietnamese catalogue, PDF 198 ↗
Indoor unitFXEQ-A →

FXEQ25AV36

Daikin · 1-way cassette

FXEQ25AV36 is a Daikin indoor unit in the FXEQ-A series, 1-way cassette type. Its rated cooling capacity is 2.8 kW according to catalogue PCVVN2507Aaprv.

Rated cooling capacity
2.8 kW
Power supply
1-phase, 220-240 V, 50 Hz
Dimensions (H×W×D)
200×840×470 mm
Weight
17 kg
Data extracted from the English catalogue; not all specifications have been manually verified. Check the source before use. Source & notes →
Open comparison tool →

FXEQ25AV36 specifications

FXEQ25AV36 specifications · PCVVN2507Aaprv
Rated capacity 4 specifications
Cooling capacity · Btu/h9,600
Cooling capacity · kW2.8
Heating capacity · Btu/h10,900
Heating capacity · kW3.2
Electrical & efficiency 3 specifications
Power supply1-phase, 220-240 V, 50 Hz
Power consumption · Cooling · kW0.027
Power consumption · Heating · kW0.023
Airflow & sound 6 specifications
Airflow rate (H/HM/M/ML/L) · Cooling · m3/min6.9/6.4/5.8/5.3/4.8
Airflow rate (H/HM/M/ML/L) · Cooling · cfm244/226/205/187/169
Airflow rate (H/HM/M/ML/L) · Heating · m3/min7.2/6.7/6.1/5.6/5.0
Airflow rate (H/HM/M/ML/L) · Heating · cfm254/237/215/198/177
Sound level (H/HM/M/ML/L) · Cooling · dB(A)32/31/30/29/28
Sound level (H/HM/M/ML/L) · Heating · dB(A)35/33/31/30/28
Dimensions & weight 3 specifications
CasingGalvanised steel plate
Dimensions (H×W×D) · mm200×840×470
Machine weight · kg17
Piping & refrigerant 3 specifications
Piping connections · Liquid (Flare) · mm6.4
Piping connections · Gas (Flare) · mm12.7
Piping connections · Drain · mmPVC26 (External Dia. 26/Internal Dia. 20)
Controls & accessories 4 specifications
Panel (Option) · ModelBYEP40AW1
Panel (Option) · ColourFresh white
Panel (Option) · Dimensions(H×W×D) · mm80×950×550
Panel (Option) · Weight · kg8.0

Catalogue source & rating conditions

Values are taken from PCVVN2507Aaprv, PDF page 199 (printed page 198). General Catalogue 2025; published on VRV.vn as Catalogue 2026 (EN).

Rated performance depends on test conditions and system combinations. Check the source notes when selecting equipment or comparing series.

Read original source notes (English)
Notes: Specifications are based on the following conditions; • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Height difference: 0 m. • Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Height difference: 0 m. • Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) • Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward. During actual operation, these values are normally somewhat higher as a result of ambient conditions. 198 stinU roodnI
View catalogue page · PDF 199

The original page preserves symbols, merged cells and accessories; not every accessory shown is supplied with the unit.

Original English catalogue, PDF page 199
Read all text from this page and its facing page
PDF page 199 VRV Indoor Units Specifications MODEL FXEQ20AV36 FXEQ25AV36 FXEQ32AV36 FXEQ40AV36 FXEQ50AV36 FXEQ63AV36 Power supply 1-phase, 220-240 V, 50 Hz Btu/h 7,500 9,600 12,300 15,400 19,100 24,200 Cooling capacity kW 2.2 2.8 3.6 4.5 5.6 7.1 Btu/h 8,500 10,900 13,600 17,100 21,500 27,300 Heating capacity kW 2.5 3.2 4.0 5.0 6.3 8.0 Power Cooling 0.026 0.027 0.034 0.046 0.048 0.067 kW consumption Heating 0.022 0.023 0.030 0.042 0.044 0.063 Casing Galvanised steel plate m3/min 6.0/5.4/4.9/4.4/4.0 6.9/6.4/5.8/5.3/4.8 8.0/7.5/7.0/6.3/5.5 9.8/8.8/7.8/7.0/6.2 12.5/11.4/10.4/9.5/8.7 15.0/13.6/12.2/11.0/9.8 Cooling Airflow rate cfm 212/191/173/155/141 244/226/205/187/169 282/265/247/222/194 346/311/275/247/219 441/402/367/335/307 530/480/431/388/346 (H/HM/M/ML/L) m3/min 6.0/5.6/5.1/4.7/4.2 7.2/6.7/6.1/5.6/5.0 8.6/8.0/7.4/6.7/6.0 10.2/9.3/8.4/7.6/6.8 14.0/12.8/11.6/10.7/9.8 16.9/15.3/13.6/12.3/11.0 Heating cfm 212/198/180/166/148 254/237/215/198/177 304/282/261/237/212 360/328/297/268/240 494/452/409/378/346 597/540/480/434/388 Sound level Cooling 30/29/28/27/26 32/31/30/29/28 35/34/33/32/30 38/37/35/33/31 38/37/35/33/31 43/41/39/37/35 dB(A) (H/HM/M/ML/L) Heating 33/31/29/28/26 35/33/31/30/28 38/36/34/33/31 41/39/37/35/33 41/39/37/36/34 46/44/42/40/38 Dimensions (H×W×D) mm 200×840×470 200×1,240×470 Machine weight kg 17 18 23 Liquid (Flare) 6.4 9.5 Piping Gas (Flare) mm 12.7 15.9 connections Drain PVC26 (External Dia. 26/Internal Dia. 20) Model BYEP40AW1 BYEP63AW1 Panel Colour Fresh white (Option) Dimensions(H×W×D) mm 80×950×550 80×1,350×550 Weight kg 8.0 10.0 Notes: Specifications are based on the following conditions; • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Height difference: 0 m. • Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Height difference: 0 m. • Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) • Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward. During actual operation, these values are normally somewhat higher as a result of ambient conditions. 198 stinU roodnI FACING PAGE — PDF page 198 Single Flow Cassette Type FXEQ-A Slim design for flexible installation Slim design Trave 447700 mmmm • The body features a compact design with a 884400 mmmm height of just 200 mm and depth 470 mm, Indoor unit 200 mm 255 mm making the installation possible in tight 80 mm ceiling spaces. 225555 mmmm • The novel smooth panel design makes dust difficult to accumulate, thus causing the cleaning more conveniently. Comfort • The swinging of horizontal and vertical swing Front view Side view flaps can be adjusted freely with the remote controller, providing 3D airflow to every corner of the room. • Control of airflow rate can be selected from 5-step control, Automatic and quiet operation mode, which provides comfortable airflow. • DC motor is adopted both in the fan and drain pump of the indoor unit, not only enhancing the energy saving performance, but also reducing the operating sound and the vibration incurred to the unit. Vertical swing flaps, Horizontal swing flaps, swinging to swinging between • While creating a cozy indoor environment, left or right within 45° 20° 70° to the unit can prevent the suspended ceiling from being soiled by adjusting its louvre angle. Easy maintenance • Drain pump is equipped as standard accessory • Maintenance with 850 mm lift. operations can be performed by removing the front panel. 197

Catalogue article on VRV.vn ↗ · Original English PDF on VRV.vn ↗