TECHNICAL SPECIFICATION SHEET · DAIKIN

FXDSQ32AVM

Indoor unit · FXDSQ-A · Concealed ceiling ducted 3D airflow

Data extracted from the English catalogue; not all specifications have been manually verified. Check the original source before use.

FXDSQ32AVM specifications
Rated capacity
Cooling capacity · Btu/h12,300
Cooling capacity · kW3.6
Heating capacity · Btu/h13,600
Heating capacity · kW4.0
Electrical & efficiency
Power supply1-phase, 220-240/220-230 V, 50/60 Hz
Power consumption *1 · Cooling · kW0.032
Power consumption *1 · Heating · kW0.028
Airflow & sound
Airflow rate (H/HM/M/ML/L) · m3/min10.0/9.3/8.6/7.9/7.2
Airflow rate (H/HM/M/ML/L) · cfm353/328/304/279/254
External static pressure · Pa10-0 *2
Sound level (H/HM/M/ML/L)*1 *3 · dB(A)34/32/30/29/27
Dimensions & weight
CasingGalvanized steel plate
Dimensions (H×W×D) · mm200×700×450
Machine weight · kg17
Piping & refrigerant
Piping connections · Liquid (Flare) · mm6.4
Piping connections · Gas (Flare) · mm12.7
Piping connections · Drain · mmPVC26 (External Dia. 26 / Internal Dia. 20)
Controls & accessories
3D Auto swing panel · Dimensions (H×W×D) · mm180×722×70
3D Auto swing panel · ColourFresh white
3D Auto swing panel · Weight · kg1.0

Source reference

PCVVN2507Aaprv · PDF page 201 · Printed page 200
General Catalogue 2025; published on VRV.vn as Catalogue 2026 (EN)

Open catalogue PDF · page 201
Model page: https://vrv.vn/spec/fxdsq32avm/

Rated performance depends on test conditions and system combinations. “—” means no value was extracted. This sheet does not replace the manufacturer’s technical documentation.

Original source notes

Extracted from the catalogue page and its facing page, where available. Notes may refer to other models or optional accessories.

Notes: Specifications are based on the following conditions;
•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 5 m, Height difference: 0 m.
•Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 5 m, Height difference: 0 m.
•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)
•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
*1: Values are based on external static pressure of 10 Pa.
*2: External static pressure is changeable to set by the remote controller. This pressure means “High static pressure - Standard”. (Factory setting is 10 Pa )
*3: The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).
200
)C°(
tniopteS
VRV Indoor Units
Cooling Heating
30°C near ceiling
Room temperature is
calculated as 27°C in the area which
is in the vicinity of the person.
24°C near floor 20°C near floor 20°C near floor
Absence Presence
Example
• When there are no 2288°°CC
people in a room, the 2277°°CC
set temperature is 2266°°CC 2266°°CC
shifted automatically.
After After Time
30 min another 30 min
stinU