Back to resultsSpecification results
Daikin FVPR-Q · Packaged — representative product image
Representative image · English catalogue, PDF 2 ↗

FVPR450QY1

Daikin · Floor standing · Duct connection · Packaged Inverter · R-410A

FVPR450QY1 is a Daikin indoor unit in the FVPR-Q · Packaged series, floor standing · duct connection · packaged inverter · r-410a type. Its reference system cooling capacity (*1) is 52.8 kW according to catalogue PCTPMT2309.

Reference system cooling capacity
52.8 kW
Power supply
3 Phase, 380–415 V, 50 Hz
Dimensions (H×W×D)
1,870×1,810×720 mm
Weight
297 kg
Data extracted from the English catalogue; not all specifications have been manually verified. Check the source before use. Source & notes →
Open comparison tool →

FVPR450QY1 specifications

FVPR450QY1 specifications · PCTPMT2309
System configuration 1 specifications
Unit combinationFVPR450QY1 + RZUR450QY1
Rated capacity 5 specifications
Cooling capacity (19.5°CWB) *1 *3 · kW52.80
Cooling capacity (19.5°CWB) *1 *3 (Max.) · kW52.80 (53.63)
Cooling capacity (19.5°CWB) *1 *3 (Max.) · Btu/h180,000 (183,000)
Cooling capacity (19°CWB) *2 *3 (Max.) · kW52.00 (52.80)
Cooling capacity (19°CWB) *2 *3 (Max.) · Btu/h177,000 (180,000)
Electrical & efficiency 4 specifications
System power consumption (19.5°CWB) *1 *3 · kW20.15
System power consumption (19°CWB) *2 *3 · kW20.00
CSPF (19°CWB) *23.71
Power supply3 Phase, 380–415 V, 50 Hz
Airflow & sound 6 specifications
Air flow rate (H) · m³/min166
Air flow rate (H) · cfm5,860
External static pressure *5 · Pa150
Fan · Motor output · kW2.2
Fan · DriveBelt Drive
Sound level · dB(A)66
Dimensions & weight 3 specifications
Casing colourIvory White
Dimensions (H×W×D) · mm1,870×1,810×720
Machine weight · kg297
Piping & refrigerant 2 specifications
Drain · mmPS 1B Internal thread
Refrigerant · TypeR-410A

Catalogue source & rating conditions

Values are taken from PCTPMT2309, PDF page 4 (printed page 5). Daikin Inverter Air Cooled Packaged · PCTPMT2309.

Rated performance depends on test conditions and system combinations. Check the source notes when selecting equipment or comparing series.

Read original source notes (English)
Note: *1. Indoor temp.: 27°CDB, 19.5°CWB / outdoor temp.: 35°CDB, 24°CWB / Equivalent piping length: 7.5 m, level difference: 0 m. *2. Indoor temp.: 27°CDB, 19°CWB / outdoor temp.: 35°CDB, 24°CWB / Equivalent piping length: 7.5 m, level difference: 0 m. *3. Capacity is net, including a deduction for cooling for indoor fan motor heat. *4. Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation these values are normally somewhat higher as a result of ambient conditions and oil recovery mode. Consider location and soundproofing measures near residences. *5. The value is the external static pressure with standard pulley. *6. Max. 40 m if the outdoor unit is lower than the indoor unit. Packaged system: cooling capacity, system power consumption and CSPF refer to the stated indoor/outdoor pairing. Outdoor model pages use the FDR pairing as the reference, except the RZUR-P models, which use their respective FVGR-P pairings. Parenthetical capacities are the source maximum values. Optional equipment is shown separately in the PDF.
View catalogue page · PDF 4

The original page preserves symbols, merged cells and accessories; not every accessory shown is supplied with the unit.

Original English catalogue, PDF page 4
Read all text from this page and its facing page
Note: *1. Indoor temp.: 27°CDB, 19.5°CWB / outdoor temp.: 35°CDB, 24°CWB / Equivalent piping length: 7.5 m, level difference: 0 m. *2. Indoor temp.: 27°CDB, 19°CWB / outdoor temp.: 35°CDB, 24°CWB / Equivalent piping length: 7.5 m, level difference: 0 m. *3. Capacity is net, including a deduction for cooling for indoor fan motor heat. *4. Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation these values are normally somewhat higher as a result of ambient conditions and oil recovery mode. Consider location and soundproofing measures near residences. *5. The value is the external static pressure with standard pulley. *6. Max. 40 m if the outdoor unit is lower than the indoor unit. Packaged system: cooling capacity, system power consumption and CSPF refer to the stated indoor/outdoor pairing. Outdoor model pages use the FDR pairing as the reference, except the RZUR-P models, which use their respective FVGR-P pairings. Parenthetical capacities are the source maximum values. Optional equipment is shown separately in the PDF.

Catalogue article on VRV.vn ↗ · Original English PDF on VRV.vn ↗