TECHNICAL SPECIFICATION SHEET · DAIKIN
FDR300QY1
Indoor unit · FDR-Q · Packaged · Duct type · Packaged Inverter · R-410A
Data extracted from the English catalogue; not all specifications have been manually verified. Check the original source before use.
| System configuration | |
|---|---|
| Unit combination | FDR300QY1 + RZUR300QY1 |
| Rated capacity | |
| Cooling capacity (19.5°CWB) *1 *3 · kW | 35.20 |
| Cooling capacity (19.5°CWB) *1 *3 (Max.) · kW | 35.20 (35.76) |
| Cooling capacity (19.5°CWB) *1 *3 (Max.) · Btu/h | 120,000 (122,000) |
| Cooling capacity (19°CWB) *2 *3 (Max.) · kW | 34.70 (35.20) |
| Cooling capacity (19°CWB) *2 *3 (Max.) · Btu/h | 118,000 (120,000) |
| Electrical & efficiency | |
| System power consumption (19.5°CWB) *1 *3 · kW | 11.28 |
| System power consumption (19°CWB) *2 *3 · kW | 11.19 |
| CSPF (19°CWB) *2 | 4.14 |
| Power supply | 3 Phase, 380–415 V, 50 Hz |
| Airflow & sound | |
| Air flow rate (H) · m³/min | 120 |
| Air flow rate (H) · cfm | 4,240 |
| External static pressure *5 · Pa | 150 |
| Fan · Motor output · kW | 1.5 |
| Fan · Drive | Belt Drive |
| Sound level · dB(A) | 59 |
| Dimensions & weight | |
| Casing colour | Galvanized Steel |
| Dimensions (H×W×D) · mm | 625×1,980×850 |
| Machine weight · kg | 177 |
| Piping & refrigerant | |
| Drain · mm | PS 1B Internal thread |
| Refrigerant · Type | R-410A |
Source reference
PCTPMT2309 · PDF page 4 · Printed page 6
Daikin Inverter Air Cooled Packaged · PCTPMT2309
Open catalogue PDF · page 4
Model page: https://vrv.vn/spec/fdr300qy1/
Rated performance depends on test conditions and system combinations. “—” means no value was extracted. This sheet does not replace the manufacturer’s technical documentation.
Original source notes
Extracted from the catalogue page and its facing page, where available. Notes may refer to other models or optional accessories.
Note: *1. Indoor temp.: 27°CDB, 19.5°CWB / outdoor temp.: 35°CDB, 24°CWB / Equivalent piping length: 7.5 m, level difference: 0 m. *2. Indoor temp.: 27°CDB, 19°CWB / outdoor temp.: 35°CDB, 24°CWB / Equivalent piping length: 7.5 m, level difference: 0 m. *3. Capacity is net, including a deduction for cooling for indoor fan motor heat. *4. Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation these values are normally somewhat higher as a result of ambient conditions and oil recovery mode. Consider location and soundproofing measures near residences. *5. The value is the external static pressure with standard pulley. *6. Max. 40 m if the outdoor unit is lower than the indoor unit. Packaged system: cooling capacity, system power consumption and CSPF refer to the stated indoor/outdoor pairing. Outdoor model pages use the FDR pairing as the reference, except the RZUR-P models, which use their respective FVGR-P pairings. Parenthetical capacities are the source maximum values. Optional equipment is shown separately in the PDF.