VAM350HVE specifications
System configuration
Heat exchange systemCounterflow total heat exchange (latent and sensible)
Heat exchange mediumNon-flammable paper
Electrical & efficiency
Power supply1 phase, 220–240 V / 220 V, 50/60 Hz
Temperature exchange efficiency · Cooling, extra high (50/60 Hz) · %65.0/65.0
Temperature exchange efficiency · Cooling, high (50/60 Hz) · %65.0/65.0
Temperature exchange efficiency · Cooling, low (50/60 Hz) · %70.0/70.0
Temperature exchange efficiency · Heating, extra high (50/60 Hz) · %79.5/79.5
Temperature exchange efficiency · Heating, high (50/60 Hz) · %79.5/79.5
Temperature exchange efficiency · Heating, low (50/60 Hz) · %81.5/82.0
Enthalpy exchange efficiency · Cooling, extra high (50/60 Hz) · %62.5/62.5
Enthalpy exchange efficiency · Cooling, high (50/60 Hz) · %62.5/62.5
Enthalpy exchange efficiency · Cooling, low (50/60 Hz) · %64.5/65.0
Enthalpy exchange efficiency · Heating, extra high (50/60 Hz) · %72.0/72.0
Enthalpy exchange efficiency · Heating, high (50/60 Hz) · %72.0/72.0
Enthalpy exchange efficiency · Heating, low (50/60 Hz) · %74.5/75.0
Power consumption · Heat exchange, extra high (50/60 Hz) · W178–193/231
Power consumption · Heat exchange, high (50/60 Hz) · W163–170/207
Power consumption · Heat exchange, low (50/60 Hz) · W132–142/145
Power consumption · Bypass, extra high (50/60 Hz) · W178–193/231
Power consumption · Bypass, high (50/60 Hz) · W163–170/207
Power consumption · Bypass, low (50/60 Hz) · W132–142/145
Fan motor output · kW0.060 × 2
Airflow & sound
Sound level · Heat exchange, extra high (50/60 Hz) · dB(A)32.0–33.0/34.5
Sound level · Heat exchange, high (50/60 Hz) · dB(A)30.0–31.5/27.5
Sound level · Heat exchange, low (50/60 Hz) · dB(A)26.5–28.5/22.0
Sound level · Bypass, extra high (50/60 Hz) · dB(A)32.5–33.5/34.5
Sound level · Bypass, high (50/60 Hz) · dB(A)31.0–32.0/27.5
Sound level · Bypass, low (50/60 Hz) · dB(A)27.0–29.0/23.0
Fan typeSirocco fan
Airflow at extra high speed (50/60 Hz) · m³/h350/350
External static pressure at extra high speed (50/60 Hz) · Pa170–185/230
Airflow at high speed (50/60 Hz) · m³/h350/350
External static pressure at high speed (50/60 Hz) · Pa145–165/80
Airflow at low speed (50/60 Hz) · m³/h275/235
External static pressure at low speed (50/60 Hz) · Pa90–102/36
Effective supply airflow ratio, extra high · %90
Dimensions & weight
CasingGalvanized steel
InsulationNon-flammable polyurethane foam
Dimensions (H×W×D) · mm306×800×879
Weight · kg31
Piping & refrigerant
Inner duct connection · mmØ150
Outer duct connection · mmØ150
Operating conditions
Ambient operating conditions−15 to 50 °CDB, up to 80% RH
Filters
Air filterMulti-directional fibre mat

Source reference

VN-PCXDHMT2111A · PDF page 10 · Printed page 9
Vietnamese source PDF · English specifications translated from the source

Open catalogue PDF · page 10
Model page: https://vrv.vn/spec/vam350hve/

Rated performance depends on test conditions and system combinations. “—” means no value was extracted. This sheet does not replace the manufacturer’s technical documentation.

Catalogue notes (summary)

Notes: Pairs are in 50/60 Hz order. The catalogue cites JIS B8628:2017 for heat exchange and sound testing. The reference table on PDF page 13 uses VAM-G test conditions. Use the main VAM-HVE tables on PDF pages 10–11.