TECHNICAL SPECIFICATION SHEET · DAIKIN

RXYMQ4AVE

Outdoor unit · VRV IV S · Cooling only / heat pump

Data extracted from the English catalogue; not all specifications have been manually verified. Check the original source before use.

RXYMQ4AVE specifications
System configuration
Capacity index100
Total capacity index of connectable indoor units · Combination (%) · 50%50
Total capacity index of connectable indoor units · Combination (%) · 100%100
Total capacity index of connectable indoor units · Combination (%) · 130%130
Maximum number of connectable indoor units6
Rated capacity
Cooling capacity · Btu/h38,200
Cooling capacity · kW11.2
Heating capacity · Btu/h42,700
Heating capacity · kW12.5
kW11.2
HP4
Electrical & efficiency
Power supply1-phase, 220-230 V/220 V, 50/60 Hz
Power consumption · Cooling · kW2.88
Power consumption · Heating · kW2.60
Capacity control · %24 to 100
Compressor · TypeHermetically sealed swing type
Compressor · Motor output (Cooling/Heating) · kW1.92
Airflow & sound
Airflow rate · m3/min76
Sound level (Cooling/Heating) · dB(A)52/54
Dimensions & weight
Casing colourIvory white (5Y7.5/1)
Dimensions (H×W×D) · mm990×940×320
Machine weight · kg71
Piping & refrigerant
Refrigerant · TypeR-410A
Refrigerant · Charge · kg2.9
Piping connections · Liquid · mm9.5 (Flare)
Piping connections · Gas · mm15.9 (Flare)
Operating conditions
Operation range · Cooling · °CDB-5 to 46
Operation range · Heating · °CWB-20 to 15.5

Source reference

PCVVN2507Aaprv · PDF page 135 · Printed page 134
General Catalogue 2025; published on VRV.vn as Catalogue 2026 (EN)

Open catalogue PDF · page 135
Model page: https://vrv.vn/spec/rxymq4ave/

Rated performance depends on test conditions and system combinations. “—” means no value was extracted. This sheet does not replace the manufacturer’s technical documentation.

Original source notes

Extracted from the catalogue page and its facing page, where available. Notes may refer to other models or optional accessories.

Notes: Specifications are based on the following conditions;
• Cooling: Indoor temp. : 27° CDB, 19° CWB, Outdoor temp. : 35° CDB, Equivalent piping length: 7.5 m, Height difference: 0 m.
• Heating: Indoor temp.: 20° CDB, Outdoor temp.: 7° CDB, 6° CWB, Equivalent piping length: 7.5 m, Height difference: 0 m.
• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode.
When there is concern for noise the surrounding area such as residences, we recommend investigating the installation location and taking soundproofing measures.
• Refrigerant charge is required.
Outdoor unit combinations
MODEL RXYMQ4AVE RXYMQ5BVM RXYMQ6BVM RXYMQ8AY1 RXYMQ9AY1
kW 11.2 14.0 16.0 22.4 24.0
HP 4 5 6 8 9
Capacity index 100 125 150 200 215
50% 50 62.5 75 100 107.5
Total capacity index
of connectable Combination (%) 100% 100 125 150 200 215
indoor units
130% 130 162.5 195 260 280
Maximum number of connectable indoor units 6 8 9 13 14
Note: Total capacity index of connectable indoor units must be 50%–130% of the capacity index of the outdoor unit.
134
seireS
S
VI
VRV
VRV IV S
Series
Notes: Specifications are based on the following conditions;
• Cooling: Indoor temp.: 27° CDB, 19° CWB, Outdoor temp.: 35° CDB, Equivalent piping length: 7.5 m, Height difference: 0 m.
• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode.
When there is concern for noise the surrounding area such as residences, we recommend investigating the installation location and taking soundproofing measures.
• Refrigerant charge is required.
Outdoor unit combinations
MODEL RXMQ4AVE RXMQ5BVM RXMQ6BVM RXMQ8AY1 RXMQ9AY1
kW 11.2 14.0 16.0 22.4 24.0
HP 4 5 6 8 9
Capacity index 100 125 150 200 215
50% 50 62.5 75 100 107.5
Total capacity index
of connectable Combination (%) 100% 100 125 150 200 215
indoor units
130% 130 162.5 195 260 280
Maximum number of connectable indoor units 6 8 9 13 14
Note: Total capacity index of connectable indoor units must be 50%–130% of the capacity index of the outdoor unit.