TECHNICAL SPECIFICATION SHEET · DAIKIN
RWEYQ12TYM
Outdoor unit · VRV IV W · Water cooled
Data extracted from the English catalogue; not all specifications have been manually verified. Check the original source before use.
| System configuration | |
|---|---|
| Combination units | – / – |
| Rated capacity | |
| Cooling capacity · Btu/h | 114,000 |
| Cooling capacity · kW | 33.5 |
| Heating capacity · Btu/h | 128,000 |
| Heating capacity · kW | 37.5 |
| Electrical & efficiency | |
| Power supply | 3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz |
| Power consumption · Cooling · kW | 7.33 |
| Power consumption · Heating · kW | 7.87 |
| Compressor · Type | Hermetically sealed scroll type |
| Compressor · Motor output · kW | 4.7 |
| Capacity control · % | 19-100 |
| Airflow & sound | |
| Sound level · dB(A) | 53 |
| Dimensions & weight | |
| Casing colour | lvory white (5Y7.5/1) |
| Dimensions (H × W × D) · mm | 1,000 × 780 × 550 |
| Machine weight (Operating weight) · kg | 147 (149) |
| Piping & refrigerant | |
| Refrigerant piping connections · Liquid · mm | 12.7 (Flare) |
| Refrigerant piping connections · Suction gas *1 · mm | 22.2 (Brazing) |
| Refrigerant piping connections · High and low pressure gas · mm | 19.1*2, 22.2*3 (Brazing) |
| Water piping connections · Water inlet | PT1 1/4B internal thread |
| Water piping connections · Water outlet | PT1 1/4B internal thread |
| Water piping connections · Drain outlet | PS1/2B internal thread |
| Refrigerant · Type | R-410A |
| Refrigerant · Charge · kg | 4.2 |
| Operating conditions | |
| Operation range (Inlet water temp.) · °C | 10 to 45 |
Source reference
PCVVN2507Aaprv · PDF page 162 · Printed page 161
General Catalogue 2025; published on VRV.vn as Catalogue 2026 (EN)
Open catalogue PDF · page 162
Model page: https://vrv.vn/spec/rweyq12tym/
Rated performance depends on test conditions and system combinations. “—” means no value was extracted. This sheet does not replace the manufacturer’s technical documentation.
Original source notes
Extracted from the catalogue page and its facing page, where available. Notes may refer to other models or optional accessories.
Notes: 1. Specifications are based on the following RWEYQ10TYM RWEYQ12TYM RWEYQ12TYM conditions: RWEYQ12TYM RWEYQ12TYM RWEYQ12TYM • Cooling: Indoor temp.: 27ºCDB, 19ºCWB / inlet 3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz water temp.:30ºC, Equivalent piping length: 7.5 m, Height difference: 0 m. 305,000 324,000 345,000 • Heating: Indoor temp.: 20ºCDB / inlet water 89.5 95.0 101 temp.: 20ºC, Equivalent piping length: 7.5 m, 345,000 365,000 386,000 Height difference: 0 m. • Sound level: Anechoic chamber conversion 101 107 113 value, measured at a point 1 m in 18.2 20.1 22.0 front of the unit at a height of 1.5 m. 19.1 21.3 23.6 During actual operation, these lvory white (5Y7.5/1) values are normally somewhat (1,000 × 780 × 550) × 3 higher as a result of ambient conditions and oil recovery mode. Hermetically sealed scroll type When there is concern for noise to 3.7 × 2 + 4.7 3.7 + 4.7 × 2 4.7 × 3 the surrounding area such as 19.1 (Flare) residences, we recommend investigating the installation 34.9 (Brazing) location and taking soundproofing 28.6*2, 34.9*3 (Brazing) measures. 2. This unit cannot be installed in the outdoors. (PT1 1/4B) × 3 internal thread Install indoors (Machine room, etc). (PT1 1/4B) × 3 internal thread 3. Hold ambient temperature at 0 – 40ºC and (PS1/2B) × 3 internal thread humidity at 80%RH or less. Heat rejection from the casing: 0.51 kW / 6 - 8 HP / hour, 0.58 kW / 147 × 3 (149 × 3) 10 - 12 HP / hour. 57 58 4. Connectable to closed type cooling tower only. 10 to 45 *1: In the case of heat pump system, suction gas pipe is not used. 19-100 *2: In the case of heat recovery system. R-410A *3: In the case of heat pump system. • Be sure to refer to the Engineering Data Book for 4.2 + 4.2 + 4.2 facility design. 162 seireS W VI VRV VRV IV W Series