TECHNICAL SPECIFICATION SHEET · DAIKIN
RSUQ5AVM
Outdoor unit · VRV S High efficiency · VRV S
Data extracted from the English catalogue; not all specifications have been manually verified. Check the original source before use.
| System configuration | |
|---|---|
| Capacity index | 125 |
| Total capacity index of connectable indoor units · Combination (%) · 50% | 62.5 |
| Total capacity index of connectable indoor units · Combination (%) · 100% | 125 |
| Total capacity index of connectable indoor units · Combination (%) · 130% | 162.5 |
| Maximum number of connectable indoor units | 8 |
| Rated capacity | |
| Cooling capacity · Btu/h | 47,800 |
| Cooling capacity · kW | 14.0 |
| kW | 14.0 |
| HP | 5 |
| Electrical & efficiency | |
| Power supply | 1-phase, 220-240 V/220-230 V, 50/60 Hz |
| Power consumption · kW | 3.44 |
| Capacity control · % | 16 to 100 |
| Compressor · Type | Hermetically sealed swing type |
| Compressor · Motor output · kW | 3.1 |
| Airflow & sound | |
| Airflow rate · m3/min | 84 |
| Sound level · dB(A) | 51 |
| Dimensions & weight | |
| Casing colour | Ivory white (5Y7.5/1) |
| Dimensions (H×W×D) · mm | 870×1,100×460 |
| Machine weight · kg | 98 |
| Piping & refrigerant | |
| Refrigerant · Type | R-410A |
| Refrigerant · Charge · kg | 4.2 |
| Piping connections · Liquid · mm | 9.5 (Flare) |
| Piping connections · Gas · mm | 15.9 (Flare) |
| Operating conditions | |
| Operation range · °CDB | -5 to 52 |
Source reference
PCVVN2507Aaprv · PDF page 126 · Printed page 125
General Catalogue 2025; published on VRV.vn as Catalogue 2026 (EN)
Open catalogue PDF · page 126
Model page: https://vrv.vn/spec/rsuq5avm/
Rated performance depends on test conditions and system combinations. “—” means no value was extracted. This sheet does not replace the manufacturer’s technical documentation.
Original source notes
Extracted from the catalogue page and its facing page, where available. Notes may refer to other models or optional accessories.
Note: Specifications are based on the following conditions; • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Height difference: 0 m. • Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode. When there is concern for noise the surrounding area such as residences, we recommend investigating the installation location and taking soundproofing measures. • Refrigerant charge is required. Outdoor unit combinations MODEL RSUQ4AVM RSUQ5AVM RSUQ6AVM RSUQ7AYM RSUQ8AYM RSUQ9AYM kW 11.2 14.0 16.0 20.0 22.4 24.0 HP 4 5 6 7 8 9 Capacity index 100 125 150 175 200 215 50% 50 62.5 75 87.5 100 107.5 Total capacity index of Combination (%) 100% 100 125 150 175 200 215 connectable indoor units 130% 130 162.5 195 227.5 260 280 Maximum number of connectable indoor units 6 8 9 11 13 14 Note: Total capacity index of connectable indoor units must be 50%–130% of the capacity index of the outdoor unit. 125
Note: Specifications are based on the following conditions; • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Height difference: 0 m. • Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Height difference: 0 m. • Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode. When there is concern for noise the surrounding area such as residences, we recommend investigating the installation location and taking soundproofing measures. • Refrigerant charge is required. Outdoor unit combinations MODEL RSUYQ4AVM RSUYQ5AVM RSUYQ6AVM RSUYQ7AYM RSUYQ8AYM kW 11.2 14.0 16.0 20.0 22.4 HP 4 5 6 7 8 Capacity index 100 125 150 175 200 50% 50 62.5 75 87.5 100 Total capacity index of Combination (%) 100% 100 125 150 175 200 connectable indoor units 130% 130 162.5 195 227.5 260 Maximum number of connectable indoor units 6 8 9 11 13 Note: Total capacity index of connectable indoor units must be 50%–130% of the capacity index of the outdoor unit. 126 seireS ycneicfifE hgiH S VRV VRV S High Efficiency Series