TECHNICAL SPECIFICATION SHEET · DAIKIN
FXVQ500NY1
Indoor unit · FXVQ-N · Ducted floor standing
Data extracted from the English catalogue; not all specifications have been manually verified. Check the original source before use.
| Rated capacity | |
|---|---|
| Cooling capacity · Btu/h | 191,000 |
| Cooling capacity · kW | 56.0 |
| Heating capacity · Btu/h | 215,000 |
| Heating capacity · kW | 63.0 |
| Electrical & efficiency | |
| Power supply | 3-phase 4-wire system, 380–415 V, 50 Hz |
| Power consumption · Cooling · kW | 2.62 |
| Power consumption · Heating · kW | 2.62 |
| Airflow & sound | |
| Sound level *1 · dB(A) | 62 |
| Fan · Motor output · kW | 3.7 |
| Fan · Airflow rate · m3/min | 165 |
| Fan · Airflow rate · cfm | 5,825 |
| Fan · External static pressure *2 · Pa | 142 |
| Fan · Drive system | Belt drive system |
| Dimensions & weight | |
| Casing colour | Ivory white (5Y7.5/1) |
| Dimensions (H × W × D) · mm | 1,900×1,470×720 |
| Machine weight · kg | 281 |
| Piping & refrigerant | |
| Piping connections · Liquid · mm | 15.9 (Brazing) |
| Piping connections · Gas · mm | 28.6 (Brazing) |
| Piping connections · Drain · mm | Rp1 (PS 1B internal thread) |
| Filters | |
| Air filter · Type | Long-life filter (anti-mould resin net) |
Source reference
PCVVN2507Aaprv · PDF page 221 · Printed page 220
General Catalogue 2025; published on VRV.vn as Catalogue 2026 (EN)
Open catalogue PDF · page 221
Model page: https://vrv.vn/spec/fxvq500ny1/
Rated performance depends on test conditions and system combinations. “—” means no value was extracted. This sheet does not replace the manufacturer’s technical documentation.
Original source notes
Extracted from the catalogue page and its facing page, where available. Notes may refer to other models or optional accessories.
Notes: Specifications are based on the following conditions; • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Height difference: 0 m. • Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Height difference: 0 m. • Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) *1: Sound level : measured when the air discharge outlet duct (2 m) is attached (anechoic chamber conversion value). It increases by approximately 5 dB(A) when the plenum chamber is installed to deliver direct airflow. *2: The value is the external static pressure with standard pulley. 220 stinU roodnI