TECHNICAL SPECIFICATION SHEET · DAIKIN
FXMQ80PAVE
Indoor unit · FXMQ-PA · Concealed ceiling ducted medium–high static pressure
Data extracted from the English catalogue; not all specifications have been manually verified. Check the original source before use.
| Rated capacity | |
|---|---|
| Cooling capacity · Btu/h | 30,700 |
| Cooling capacity · kW | 9.0 |
| Heating capacity · Btu/h | 34,100 |
| Heating capacity · kW | 10.0 |
| Electrical & efficiency | |
| Power supply | 1-phase, 220-240 V/220 V, 50/60 Hz |
| Power consumption · Cooling · kW | 0.185 *1 |
| Power consumption · Heating · kW | 0.173 *1 |
| Airflow & sound | |
| Airflow rate (HH/H/L) · m3/min | 25/22.5/20 |
| Airflow rate (HH/H/L) · cfm | 883/794/706 |
| External static pressure · Pa | 50-200 (100) *2 |
| Sound level (HH/H/L) · dB(A) | 43/41/39 |
| Dimensions & weight | |
| Casing | Galvanised steel plate |
| Dimensions (H×W×D) · mm | 300×1,000×700 |
| Machine weight · kg | 35 |
| Piping & refrigerant | |
| Piping connections · Liquid (Flare) · mm | 9.5 |
| Piping connections · Gas (Flare) · mm | 15.9 |
| Piping connections · Drain · mm | VP25 (External Dia. 32/Internal Dia. 25) |
Source reference
PCVVN2507Aaprv · PDF page 209 · Printed page 208
General Catalogue 2025; published on VRV.vn as Catalogue 2026 (EN)
Open catalogue PDF · page 209
Model page: https://vrv.vn/spec/fxmq80pave/
Rated performance depends on test conditions and system combinations. “—” means no value was extracted. This sheet does not replace the manufacturer’s technical documentation.
Original source notes
Extracted from the catalogue page and its facing page, where available. Notes may refer to other models or optional accessories.
Notes: Specifications are based on the following conditions; • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Height difference: 0 m. • Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Height difference: 0 m. • Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) • Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions. *1: Power consumption values are based on conditions of rated external static pressure. *2: External static pressure can be modified using a remote controller that offers seven (FXMQ20-32PA), thirteen (FXMQ40PA), fourteen (FXMQ50-125PA) or ten (FXMQ140PA) levels of control. These values indicate the lowest and highest possible static pressures. The rated static pressure is 50 Pa for FXMQ20-32PA and 100 Pa for FXMQ40-140PA. 208 stinU roodnI
Notes: ”Airflow rate auto adjustment function” can be adjusted within ±10% of rated FXMQ-PA has table of external static pressure vs. power input of DC fan. airflow. (Refer to Engineering Data Book for details) 3. Actual duct resistance is calculated according to 1 and 2. ”Airflow rate auto adjustment function” should be used at field setting only. 4. Fan speed is automatically adjusted to produce rated airflow. Separate drain pipe and inspection opening Drain pan maintenance check hole