TECHNICAL SPECIFICATION SHEET · DAIKIN
FXDSQ50AVM
Indoor unit · FXDSQ-A · Concealed ceiling ducted 3D airflow
Data extracted from the English catalogue; not all specifications have been manually verified. Check the original source before use.
| Rated capacity | |
|---|---|
| Cooling capacity · Btu/h | 19,100 |
| Cooling capacity · kW | 5.6 |
| Heating capacity · Btu/h | 21,500 |
| Heating capacity · kW | 6.3 |
| Electrical & efficiency | |
| Power supply | 1-phase, 220-240/220-230 V, 50/60 Hz |
| Power consumption *1 · Cooling · kW | 0.049 |
| Power consumption *1 · Heating · kW | 0.045 |
| Airflow & sound | |
| Airflow rate (H/HM/M/ML/L) · m3/min | 15.0/14.0/13.0/11.5/10.5 |
| Airflow rate (H/HM/M/ML/L) · cfm | 530/494/459/406/371 |
| External static pressure · Pa | 10-0 *2 |
| Sound level (H/HM/M/ML/L)*1 *3 · dB(A) | 39/37/35/33/31 |
| Dimensions & weight | |
| Casing | Galvanized steel plate |
| Dimensions (H×W×D) · mm | 200×900×450 |
| Machine weight · kg | 20 |
| Piping & refrigerant | |
| Piping connections · Liquid (Flare) · mm | 6.4 |
| Piping connections · Gas (Flare) · mm | 12.7 |
| Piping connections · Drain · mm | PVC26 (External Dia. 26 / Internal Dia. 20) |
| Controls & accessories | |
| 3D Auto swing panel · Dimensions (H×W×D) · mm | 180×922×70 |
| 3D Auto swing panel · Colour | Fresh white |
| 3D Auto swing panel · Weight · kg | 1.5 |
Source reference
PCVVN2507Aaprv · PDF page 201 · Printed page 200
General Catalogue 2025; published on VRV.vn as Catalogue 2026 (EN)
Open catalogue PDF · page 201
Model page: https://vrv.vn/spec/fxdsq50avm/
Rated performance depends on test conditions and system combinations. “—” means no value was extracted. This sheet does not replace the manufacturer’s technical documentation.
Original source notes
Extracted from the catalogue page and its facing page, where available. Notes may refer to other models or optional accessories.
Notes: Specifications are based on the following conditions; •Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 5 m, Height difference: 0 m. •Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 5 m, Height difference: 0 m. •Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) •Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions. *1: Values are based on external static pressure of 10 Pa. *2: External static pressure is changeable to set by the remote controller. This pressure means “High static pressure - Standard”. (Factory setting is 10 Pa ) *3: The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 dB(A). 200 )C°( tniopteS VRV Indoor Units Cooling Heating 30°C near ceiling Room temperature is calculated as 27°C in the area which is in the vicinity of the person. 24°C near floor 20°C near floor 20°C near floor Absence Presence Example • When there are no 2288°°CC people in a room, the 2277°°CC set temperature is 2266°°CC 2266°°CC shifted automatically. After After Time 30 min another 30 min stinU roodnI