TECHNICAL SPECIFICATION SHEET · DAIKIN

FXAQ32BVM

Indoor unit · FXAQ-B · Wall mounted

Data extracted from the English catalogue; not all specifications have been manually verified. Check the original source before use.

FXAQ32BVM specifications
Rated capacity
Cooling capacity · Btu/h12,300
Cooling capacity · kW3.6
Heating capacity · Btu/h13,600
Heating capacity · kW4.0
Electrical & efficiency
Power supply1-phase, 220-240 V/220-230 V, 50/60 Hz
Power consumption · Cooling · kW0.020
Power consumption · Heating · kW0.020
Airflow & sound
Airflow rate (H/HM/M/ML/L) · m³/min10/9.2/8.3/ 7.2/6.5
Airflow rate (H/HM/M/ML/L) · cfm353/325/293/ 254/229
Sound level (H/HM/M/ML/L) · Cooling · dB(A)34/31/29/ 26/25
Sound level (H/HM/M/ML/L) · Heating · dB(A)34/31/28/ 26/24
Dimensions & weight
Casing / ColourResin / White N9.5
Dimensions (H×W×D) · mm295×858×245
Machine weight · kg12
Piping & refrigerant
Piping connections · Liquid · mm6.4
Piping connections · Gas · mm12.7
Piping connections · Drain · mmVP14 (External Dia. 16, Internal Dia. 14)

Source reference

PCVVN2507Aaprv · PDF page 217 · Printed page 216
General Catalogue 2025; published on VRV.vn as Catalogue 2026 (EN)

Open catalogue PDF · page 217
Model page: https://vrv.vn/spec/fxaq32bvm/

Rated performance depends on test conditions and system combinations. “—” means no value was extracted. This sheet does not replace the manufacturer’s technical documentation.

Original source notes

Extracted from the catalogue page and its facing page, where available. Notes may refer to other models or optional accessories.

Note: Specifications are based on the following conditions;
• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Height difference: 0 m.
• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Height difference: 0 m.
• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details) 216
• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
stinU
roodnI
Bubble controlling technology
New motor-operated valve features an integrated rectifying plate
that stabilizes refrigerant flow by suppressing turbulence and bubbles,
resulting in smoother operation and reduced flow noise.